Entity Name: | SD RESTORATION, INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
SD RESTORATION, INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 02 Mar 2010 (15 years ago) |
Date of dissolution: | 27 Sep 2013 (12 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2013 (12 years ago) |
Document Number: | P10000018888 |
FEI/EIN Number |
272050794
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 16264 NW 24TH ST, PEMBROKE PINES, FL, 33028 |
Mail Address: | 16264 NW 24TH ST, PEMBROKE PINES, FL, 33028 |
ZIP code: | 33028 |
County: | Broward |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
TORRES HENRY | Director | 16264 NW 24TH ST, PEMBROKE PINES, FL, 3328 |
TORRES HENRY | President | 16264 NW 24TH ST, PEMBROKE PINES, FL, 3328 |
GOMEZ BERNARDO | Director | 15020 S.W. 80 TERR, MIAMI, FL, 33193 |
TORRES HENRY | Agent | 16264 NW 24TH ST, PEMBROKE PINES, FL, 33028 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G11000099303 | TOGO DRYWALL & PLASTERING | EXPIRED | 2011-10-08 | 2016-12-31 | - | 16264 NW 24TH ST, PEMBROKE PINES, FL, 33028 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2013-09-27 | - | - |
REINSTATEMENT | 2011-10-07 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2011-09-23 | - | - |
AMENDMENT | 2011-04-22 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2012-02-25 |
REINSTATEMENT | 2011-10-07 |
Amendment | 2011-04-22 |
Domestic Profit | 2010-03-02 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339050668 | 0418800 | 2013-05-07 | 7500 NW 25TH ST UNIT 114, MIAMI, FL, 33122 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Accident |
Activity Nr | 817446 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 C01 |
Issuance Date | 2013-09-26 |
Current Penalty | 3430.04 |
Initial Penalty | 4900.0 |
Final Order | 2013-10-18 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. On or about May 6th, 2013, at the above address jobsite, a Baker scaffold was not restrained from tipping while the height to base ratio exceeded 4:1. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 F07 |
Issuance Date | 2013-09-26 |
Current Penalty | 1960.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-10-18 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: On or about May 6th,2012, at the above address jobsite, a Baker scaffold was not erected by a competent person. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260452 C03 |
Issuance Date | 2013-09-26 |
Current Penalty | 1960.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-10-18 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(c)(3): Frames and panels were not joined together vertically by coupling or stacking pins or equivalent means: On or about May 6th, 2013, at the above address jobsite, the employer had a Baker scaffold with frames that were not joined together by coupling or stacking pins. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260452 W09 |
Issuance Date | 2013-09-26 |
Current Penalty | 1960.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-10-18 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(w)(9): Caster stems and wheel stems were not pinned or otherwise secured in scaffold legs or adjustment screws. On or about May 6th, 2013, at the above address jobsite, the employer had a Baker scaffold with caster stems that were not pinned or secured to the scaffold legs. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2013-09-26 |
Abatement Due Date | 2013-10-30 |
Current Penalty | 1960.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-10-18 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: On or about May 6th, 2013, at the above address jobsite, the employer did not provide training to employees using ladders. |
Date of last update: 03 Apr 2025