344971114
|
0418800
|
2020-10-09
|
1 BETTY ROSS DRIVE, KEY WEST, FL, 33040
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-10-09
|
Emphasis |
L: FALL
|
Case Closed |
2021-02-01
|
Related Activity
Type |
Referral |
Activity Nr |
1669258 |
Safety |
Yes |
|
|
344420583
|
0418800
|
2019-10-30
|
2319 N. ROOSEVELT BLVD, KEY WEST, FL, 33040
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-10-30
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2021-09-23
|
Related Activity
Type |
Inspection |
Activity Nr |
1443317 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1442066 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1442062 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1444411 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1443272 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260701 B |
Issuance Date |
2020-03-17 |
Current Penalty |
3711.0 |
Initial Penalty |
7422.0 |
Contest Date |
2020-04-10 |
Final Order |
2021-04-16 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: At Hotel: On or about 10/30/2019 and days prior, the employer exposed employees to impalement hazards, in that rebar on the 2nd floor and 3rd floor deck were not equipped with protective caps. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2020-03-17 |
Abatement Due Date |
2020-04-03 |
Current Penalty |
13394.0 |
Initial Penalty |
20781.0 |
Contest Date |
2020-04-10 |
Final Order |
2021-04-16 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: At Hotel: On or about 10/30/2019 and at times prior, the employer exposed employees to fall hazards of approximately 20 feet, in that fall protection was not utilized by employees while performing rebar work at the edge of the 3rd floor deck. Bella Construction of Key West, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(1), which was contained in OSHA inspection number 1442058, citation number 01, item number 001, issued on 09/26/2018, with respect to a workplace located at 441 Airport Drive N., Summerland Key, Florida 33042, which became a final order on 11/26/2018. |
|
|
343363016
|
0418800
|
2018-08-01
|
441 AIRPORT DR. N, SUMMERLAND KEY, FL, 33042
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-08-01
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2018-12-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2018-09-26 |
Abatement Due Date |
2018-10-09 |
Current Penalty |
1658.4 |
Initial Penalty |
2764.0 |
Final Order |
2018-11-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about August 1, 2018, on the top deck of the new home under construction, employees worked without fall protection, exposing them to a fall hazard of approximately 13ft 8 inches. |
|
|
343168803
|
0418800
|
2018-05-02
|
159 SIMONTON ST., KEY WEST, FL, 33040
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-05-02
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-10-01
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2018-08-06 |
Abatement Due Date |
2018-08-16 |
Current Penalty |
6337.8 |
Initial Penalty |
9054.0 |
Final Order |
2018-08-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 2 May, 2018, on the roof of the townhomes being constructed, an employee was working without fall protection, exposing the employee to a fall hazard of approximately 20 feet. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2018-08-06 |
Abatement Due Date |
2018-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-08-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee In the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about May 2, 2018, at Building #500, Unit 119-125, the employer did not instruct employees of the hazards associated with falls while engaged in roofing activity on a working and walking platform located on a residential roof. |
|
|
342613924
|
0418800
|
2017-08-31
|
1107 SOUTHARD STREET, KEY WEST, FL, 33040
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-31
|
Emphasis |
L: FALL, P: FALL
|
|
342577939
|
0418800
|
2017-08-22
|
18 AQUAMARINE BIG COPPITT, KEY WEST, FL, 33040
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-22
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-12-08
|
Related Activity
Type |
Inspection |
Activity Nr |
1257751 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2017-10-02 |
Current Penalty |
2281.2 |
Initial Penalty |
3802.0 |
Final Order |
2017-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: On or about 22 August 2017, at the above addressed jobsite, an employee accessed a scaffold by stepping on the top step of the 9-foot A-frame ladder, exposing the employee to a fall hazard of approximately 9 feet. |
|
|
339604753
|
0418800
|
2014-02-26
|
3850 N. ROOSEVELT BLVD, KEY WEST, FL, 33040
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-02-26
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2014-05-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2014-04-03 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. On or about February 26th, 2014, at the above addressed job site, an employee was exposed to an approximate 7 foot fall when using an A frame ladder as a straight ladder when gaining access to a concrete column. |
|
|