Entity Name: | 1ST CLASS CONSTRUCTION INCORPORATED |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
1ST CLASS CONSTRUCTION INCORPORATED is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 08 Jul 2009 (16 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 30 May 2017 (8 years ago) |
Document Number: | P09000058257 |
FEI/EIN Number |
270512732
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 11039 MULLER RD, FORT PIERCE, FL, 34945, US |
Mail Address: | 11039 MULLER RD, FT PIERECE, FL, 34945 |
ZIP code: | 34945 |
County: | St. Lucie |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
TOTH DANIEL JJR. | President | 11039 MULLER RD, FORT PIERCE, FL, 34945 |
TOTH DANIEL JJR. | Treasurer | 11039 MULLER RD, FORT PIERCE, FL, 34945 |
TOTH DANIEL JJR. | Secretary | 11039 MULLER RD, FORT PIERCE, FL, 34945 |
MERRITT BONNIE | Vice President | 2759 Rainbow Drive, Fort Pierce, FL, 34981 |
TOTH DANIEL JJR. | Agent | 11039 MULLER RD, FORT PIERCE, FL, 34945 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2020-01-05 | 11039 MULLER RD, FORT PIERCE, FL 34945 | - |
REGISTERED AGENT ADDRESS CHANGED | 2020-01-05 | 11039 MULLER RD, FORT PIERCE, FL 34945 | - |
AMENDMENT | 2017-05-30 | - | - |
CHANGE OF MAILING ADDRESS | 2017-05-30 | 11039 MULLER RD, FORT PIERCE, FL 34945 | - |
REGISTERED AGENT NAME CHANGED | 2011-01-07 | TOTH, DANIEL J, JR. | - |
REINSTATEMENT | 2010-12-09 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2010-09-24 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-11 |
ANNUAL REPORT | 2024-02-03 |
ANNUAL REPORT | 2023-01-14 |
ANNUAL REPORT | 2022-02-12 |
ANNUAL REPORT | 2021-02-06 |
ANNUAL REPORT | 2020-01-05 |
ANNUAL REPORT | 2019-01-25 |
ANNUAL REPORT | 2018-01-13 |
Amendment | 2017-05-30 |
ANNUAL REPORT | 2017-01-09 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342536125 | 0418800 | 2017-08-10 | 1800 SE COVE ROAD, STUART, FL, 34997 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-10-23 |
Current Penalty | 1303.8 |
Initial Penalty | 2173.0 |
Final Order | 2017-11-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about August 10, 2017, at the above addressed site, employees were exposed to a fall hazard of approximately 11 feet 4 inches when performing plywood sheathing installation work on a residential building under construction while not being protected from falling to the lower level. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2017-10-23 |
Abatement Due Date | 2017-11-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-11-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about August 10, 2017, at the above addressed site, employees were exposed to a fall hazard when installing plywood sheathing to the roof of a residence under construction prior to being provided with a training program that would enable them to recognize the hazards associated with falling. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260403 B02 |
Issuance Date | 2017-10-23 |
Current Penalty | 1303.8 |
Initial Penalty | 2173.0 |
Final Order | 2017-11-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about August 10, 2017, at the above addressed site, employees were exposed to an electrical shock hazard when using a 4 by 4 inch metal outlet box with flexible electrical wiring as an extension cord to power carpentry hand tools and an air compressor which was not in accordance with the manufactures instructions. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19101200 G08 |
Issuance Date | 2017-10-23 |
Abatement Due Date | 2017-11-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-11-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: On or about May 24, 2017, at the above addressed site, employees were using chemicals including but not limited to Shell Motor Oil and Gasoline while the employer did not maintain the safety data sheets for those products at the worksite. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19260416 E01 |
Issuance Date | 2017-10-23 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-11-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: On or about August 10, 2017, at the above addressed site, employees were exposed to an electrical shock hazard when using a worn and frayed electrical cord leading from a generator to power carpentry hand tools and an air compressor. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4479397201 | 2020-04-27 | 0455 | PPP | 11039 MULLER RD, FORT PIERCE, FL, 34945 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3618518410 | 2021-02-05 | 0455 | PPS | 11039 Muller Rd, Fort Pierce, FL, 34945-2322 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 02 Apr 2025
Sources: Florida Department of State