Search icon

NAPLES DRYWALL & PLASTERING, INC. - Florida Company Profile

Company Details

Entity Name: NAPLES DRYWALL & PLASTERING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

NAPLES DRYWALL & PLASTERING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 11 Jun 2009 (16 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 12 Oct 2010 (15 years ago)
Document Number: P09000050965
FEI/EIN Number 800427607

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6226 ADKINS AVE, NAPLES, FL, 34112, US
Mail Address: 6226 ADKINS AVE, NAPLES, FL, 34112, US
ZIP code: 34112
County: Collier
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TATE MARK President 6226 ADKINS AVE, NAPLES, FL, 34112
TATE MARK Agent 6226 ADKINS AVE, NAPLES, FL, 34112

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2019-02-22 6226 ADKINS AVE, NAPLES, FL 34112 -
REGISTERED AGENT NAME CHANGED 2015-09-01 TATE, MARK -
CHANGE OF PRINCIPAL ADDRESS 2011-01-05 6226 ADKINS AVE, NAPLES, FL 34112 -
CHANGE OF MAILING ADDRESS 2011-01-05 6226 ADKINS AVE, NAPLES, FL 34112 -
REINSTATEMENT 2010-10-12 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2010-09-24 - -

Documents

Name Date
ANNUAL REPORT 2025-02-14
ANNUAL REPORT 2024-02-23
ANNUAL REPORT 2023-02-02
ANNUAL REPORT 2022-01-26
ANNUAL REPORT 2021-01-20
ANNUAL REPORT 2020-01-15
ANNUAL REPORT 2019-02-22
ANNUAL REPORT 2018-01-12
ANNUAL REPORT 2017-01-06
ANNUAL REPORT 2016-01-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343113429 0418800 2018-04-25 185 PAGO PAGO DRIVE WEST, NAPLES, FL, 34113
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-04-25
Emphasis L: FALL, P: FALL
Case Closed 2019-10-15

Related Activity

Type Referral
Activity Nr 1330937
Safety Yes
Type Inspection
Activity Nr 1311545
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-08-06
Abatement Due Date 2018-08-30
Current Penalty 1663.2
Initial Penalty 2772.0
Final Order 2018-08-31
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, employees were exposed to a fall hazard while using a 4-tier scaffold that lacked planking. Instance 1: An employee was exposed to a fall hazard of 12ft while installing black paper from the 2nd tier fabricated frame scaffold. Instance 2: An employee was exposed to a fall hazard of 30ft while installing corner beads from the 4th tier fabricated frame scaffold. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2018-08-06
Abatement Due Date 2018-08-30
Current Penalty 1663.2
Initial Penalty 2772.0
Final Order 2018-08-31
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, employees were exposed to a fall hazard while using a 4-tier scaffold that lacked base plates and mudsills. Instance 1: An employee was exposed to a fall hazard of 12ft while working from a scaffold that was not installed with base plates. Instance 2: An employee was exposed to a fall hazard of 30ft while working from a scaffold that was not installed with base plates. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2018-08-06
Abatement Due Date 2018-08-30
Current Penalty 1663.2
Initial Penalty 2772.0
Final Order 2018-08-31
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, employees were exposed to a fall hazard while using a 4-tier scaffold that lacked guardrails. Instance 1: An employee was exposed to a fall hazard of 12ft while installing black paper from the 2nd tier fabricated frame scaffold that lacked guardrails. Instance 2: An employee was exposed to a fall hazard of 30ft while installing corner beads from the 4th tier fabricated frame scaffold that lacked guardrails. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2018-08-06
Abatement Due Date 2018-08-30
Current Penalty 1663.2
Initial Penalty 2772.0
Final Order 2018-08-31
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. End frames were used as a means of access: On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, employees were exposed to a fall hazard while using a 4-tier scaffold that lacked a ladder to access all tiers of the scaffold. Instance 1: An employee was exposed to a fall hazard of 12ft while climbing down the end frames from the 2nd tier of the fabricated frame scaffold. Instance 2: An employee was exposed to a fall hazard of 30ft while climbing down the end frames from the 2nd tier of the fabricated frame scaffold. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2018-08-06
Abatement Due Date 2018-09-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-08-31
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, the employer did not ensure a competent person inspected a 4-tier scaffold with several deficiencies exposing employees to fall hazards. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.