Search icon

CERTIFIED CONSTRUCTION GROUP INC. - Florida Company Profile

Company Details

Entity Name: CERTIFIED CONSTRUCTION GROUP INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

CERTIFIED CONSTRUCTION GROUP INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 11 Feb 2009 (16 years ago)
Date of dissolution: 25 Sep 2020 (5 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2020 (5 years ago)
Document Number: P09000013385
FEI/EIN Number 264248672

Federal Employer Identification (FEI) Number assigned by the IRS.

Mail Address: 4111 Louis Ave, Holiday, FL, 34691, US
Address: 4111 LOUIS AVE, SUITE 14, HOLIDAY, FL, 34691
ZIP code: 34691
County: Pasco
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MCNAMARA BRIAN J President 4111 Louis Ave, Holiday, FL, 34691
WELLS RICHARD E Vice President 4303 Oakfield Ave, Holiday, FL, 34691
MCNAMARA BRIAN J Agent 4111 Louis Ave, Holiday, FL, 34691

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2020-09-25 - -
CHANGE OF MAILING ADDRESS 2019-07-11 4111 LOUIS AVE, SUITE 14, HOLIDAY, FL 34691 -
REGISTERED AGENT ADDRESS CHANGED 2019-07-11 4111 Louis Ave, Suite 14, Holiday, FL 34691 -

Documents

Name Date
ANNUAL REPORT 2019-07-11
ANNUAL REPORT 2018-03-14
ANNUAL REPORT 2017-02-19
ANNUAL REPORT 2016-03-28
ANNUAL REPORT 2015-05-03
ANNUAL REPORT 2014-03-03
ANNUAL REPORT 2013-01-26
ANNUAL REPORT 2012-02-13
ANNUAL REPORT 2011-02-28
ANNUAL REPORT 2010-05-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337530026 0420600 2012-11-21 7504 NEEDLELEAF PLACE, TAMPA, FL, 33610
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2012-11-21
Emphasis L: EISAOF, L: EISAX, L: FALL, P: FALL
Case Closed 2012-12-26

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2012-12-12
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2012-12-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a. At the site employee was exposed to eye and face injuries, in that, while using a nail gun he was not wearing safety glasses. On or about 11/22/2012.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2012-12-12
Abatement Due Date 2012-12-24
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2012-12-21
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety nets systems. a. At the site employees were exposed to a fall hazard of 18 feet, in that, they were installing sihingles with no fall protection. On or about 11/21/2012.
Citation ID 01003
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2012-12-12
Abatement Due Date 2012-12-24
Current Penalty 240.0
Initial Penalty 400.0
Final Order 2012-12-21
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:. a. At the site employees were using Mule- Hide fibrated emulsion roof coating. with no training in the use of the hazards associated with this product suchas but not limited to, eye and skin irritation, irritation of the digestive tract, and nervous system depression, , prolonged and repeated overexposure may cause permanent brain, and or nervous system damage. Can cause dermatitis, sanding dust inhalation may cause lung damage. Intentional misuse through inhalation may be harmful or fatal.