Search icon

MADSTAD ENGINEERING INC. - Florida Company Profile

Company Details

Entity Name: MADSTAD ENGINEERING INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

MADSTAD ENGINEERING INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 10 Dec 2008 (16 years ago)
Document Number: P08000107358
FEI/EIN Number 263858009

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1451 E. Jefferson St., Brooksville, FL, 34601, US
Mail Address: 1451 E. Jefferson St., Brooksville, FL, 34601, US
ZIP code: 34601
County: Hernando
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Long James R President 1451 E. Jefferson St., Brooksville, FL, 34601
Long Jessica L Vice President 1451 E. Jefferson St., Brooksville, FL, 34601
Long James R Agent 1451 E. Jefferson St., Brooksville, FL, 34601

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2023-04-05 Long, James R -
CHANGE OF PRINCIPAL ADDRESS 2016-04-27 1451 E. Jefferson St., Brooksville, FL 34601 -
CHANGE OF MAILING ADDRESS 2016-04-27 1451 E. Jefferson St., Brooksville, FL 34601 -
REGISTERED AGENT ADDRESS CHANGED 2016-04-27 1451 E. Jefferson St., Brooksville, FL 34601 -

Documents

Name Date
ANNUAL REPORT 2024-04-09
ANNUAL REPORT 2023-04-05
ANNUAL REPORT 2022-04-22
ANNUAL REPORT 2021-04-13
ANNUAL REPORT 2020-04-16
ANNUAL REPORT 2019-04-23
ANNUAL REPORT 2018-04-12
ANNUAL REPORT 2017-04-25
ANNUAL REPORT 2016-04-27
ANNUAL REPORT 2015-04-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340631068 0420600 2015-05-14 20721 HWY 301, DADE CITY, FL, 33523
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2015-05-14
Emphasis N: AMPUTATE, L: FORKLIFT
Case Closed 2015-10-08

Related Activity

Type Complaint
Activity Nr 981738
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2015-08-20
Abatement Due Date 2015-10-07
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. Shop - the employer did not provide forklift operator training for employees driving a Clark Equipment C500-50 forklift. Violation observed on or about 5/14/15.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2015-08-20
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. Shop - Employees were exposed to an amputation hazard while operating the Accurpress 7606 Shearpress Sales Hydraulic Press Brake, in that, the employee's hands were at the point of operation when holding up parts to be bent. Violation observed on or about 5/14/15.
Citation ID 02001
Citaton Type Other
Standard Cited 19100107 B05 I
Issuance Date 2015-08-20
Abatement Due Date 2015-08-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(i): 29 CFR 1910.107(b)(5)(I): There were no visible gauges(s), audible alarm(s) or pressure activated device(s) installed on paint spray booth(s) to indicate or ensure that the required air velocity was maintained: a. Shop - dry spray booth used for powder coating did not have visible gauges(s), audible alarm(s) or pressure activated device(s) installed on paint spray booth to indicate or ensure required air velocity. Violation observed on or about 5/14/15.
Citation ID 02002
Citaton Type Other
Standard Cited 19100107 B09
Issuance Date 2015-08-20
Abatement Due Date 2015-10-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a. Shop - materials such as, but not limited to flammable liquids, boxes and wood were stored adjacent to the exterior wall of the dry spray booth. Violation observed on or about 5/14/15.
Citation ID 02003
Citaton Type Other
Standard Cited 19100107 D03
Issuance Date 2015-08-20
Abatement Due Date 2015-08-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 11
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(d)(3): The spray booth did not have an independent exhaust duct system discharging to the exterior of the building: a Shop - dry spray booth exhaust emptied into the shop and not outside. Violation observed on or about 5/14/15.
Citation ID 02004
Citaton Type Other
Standard Cited 19100107 H12
Issuance Date 2015-08-20
Abatement Due Date 2015-10-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(h)(12): All areas used for spraying, including the interior of the booth, were not protected by an automatic sprinklers or other approved automatic extinguishing equipment: a. Shop - dry spray booth did not have sprinklers or automatic extinguishing equipment. Violation observed on or about 5/14/15.
Citation ID 02005
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2015-08-20
Abatement Due Date 2015-10-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. Shop - when respirators were required for dry spraying operations, the employer did not provide a written respiratory protection program. Violation observed on or about 5/14/15.
Citation ID 02006
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2015-08-20
Abatement Due Date 2015-10-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Shop - when respirators were required for dry spraying operations, the employer did not provide medical evaluations. Violation observed on or about 5/14/15.
Citation ID 02007
Citaton Type Other
Standard Cited 19100134 F01
Issuance Date 2015-08-20
Abatement Due Date 2015-10-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. Shop - during spraying operations where respirators were required, the employer did not provide fit testing. Violation observed on or about 5/14/15.
Citation ID 02008
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2015-08-20
Abatement Due Date 2015-10-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 11
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. Shop - the employer did not have a written hazard communication program for employees exposed to chemical products such as, but not limited to Tiger Drylac powder coats and MEK. Violation observed on or about 5/14/15.
Citation ID 02009
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2015-08-20
Abatement Due Date 2015-10-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-11
Nr Instances 1
Nr Exposed 11
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. Shop - employees exposed to chemical products such as, but not limited to Tiger Drylac powder coats and MEK, were not provided hazard communication training. Violation observed on or about 5/14/15.

Date of last update: 03 Apr 2025

Sources: Florida Department of State