Entity Name: | JAMES ROOFING SERVICES, INC. |
Jurisdiction: | FLORIDA |
Filing Type: | Domestic Profit |
Status: | Active |
Date Filed: | 07 Aug 2008 (17 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 08 Oct 2010 (14 years ago) |
Document Number: | P08000074197 |
FEI/EIN Number | 263135009 |
Address: | 7177 30TH AVE NORTH, ST. PETERSBURG, FL, 33710, US |
Mail Address: | 7177 30TH AVE NORTH, ST. PETERSBURG, FL, 33710, US |
ZIP code: | 33710 |
County: | Pinellas |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
JAMES II STEVEN T | Agent | 7177 30TH AVE NORTH, ST. PETERSBURG, FL, 33710 |
Name | Role | Address |
---|---|---|
JAMES II STEVEN T | President | 7177 30TH AVE NORTH, ST. PETERSBURG, FL, 33710 |
Name | Role | Address |
---|---|---|
JAMES STEVEN T | Vice President | 7177 30TH AVE NORTH, ST. PETERSBURG, FL, 33710 |
Name | Role | Address |
---|---|---|
JAMES LORI D | Secretary | 7177 30TH AVE NORTH, ST. PETERSBURG, FL, 33710 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2023-02-27 | JAMES II, STEVEN T | No data |
REGISTERED AGENT ADDRESS CHANGED | 2021-01-27 | 7177 30TH AVE NORTH, ST. PETERSBURG, FL 33710 | No data |
CHANGE OF PRINCIPAL ADDRESS | 2020-05-28 | 7177 30TH AVE NORTH, ST. PETERSBURG, FL 33710 | No data |
CHANGE OF MAILING ADDRESS | 2020-05-28 | 7177 30TH AVE NORTH, ST. PETERSBURG, FL 33710 | No data |
REINSTATEMENT | 2010-10-08 | No data | No data |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2010-09-24 | No data | No data |
Name | Date |
---|---|
ANNUAL REPORT | 2024-01-10 |
ANNUAL REPORT | 2023-02-27 |
ANNUAL REPORT | 2022-01-26 |
ANNUAL REPORT | 2021-01-27 |
ANNUAL REPORT | 2020-01-16 |
ANNUAL REPORT | 2019-04-03 |
ANNUAL REPORT | 2018-03-13 |
ANNUAL REPORT | 2017-02-03 |
ANNUAL REPORT | 2016-01-15 |
ANNUAL REPORT | 2015-01-20 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340183482 | 0420600 | 2015-01-15 | 2310 DENMARK STREET BLDG 18A, CLEARWATER, FL, 33763 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B03 |
Issuance Date | 2015-01-20 |
Current Penalty | 5390.0 |
Initial Penalty | 7700.0 |
Contest Date | 2015-02-18 |
Final Order | 2015-07-29 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems or personal fall arrest systems: a. On or about January 15, 2015, employees were exposed to the hazard of falling approximately 32 feet while loading and unloading roofing material in the hoisting area, on flat residential roof, without being protected from falling. James Roofing Services, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 315498055, citation number 1, item number 1 and was affirmed as a final order on May 04, 2011, with respect to a workplace located at 2816 Countrybrook Drive, Palm Harbor, FL, 34684. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260502 K03 |
Issuance Date | 2015-01-20 |
Abatement Due Date | 2015-02-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2015-02-18 |
Final Order | 2015-07-29 |
Nr Instances | 1 |
Nr Exposed | 13 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(k)(3): A copy of the fall protection plan with all approved changes shall be maintained at the job site: a. On or about January 15, 2015, employees were exposed to the hazard of falling approximately 32 feet while tearing off the old roof and installing tar on a flat residential roof. The employees were using the safety monitoring system but did not have a written fall protection plan at the jobsite. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2011-03-24 |
Emphasis | S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, L: FALL |
Case Closed | 2016-01-01 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2011-04-15 |
Abatement Due Date | 2011-04-20 |
Current Penalty | 3675.0 |
Initial Penalty | 4900.0 |
Nr Instances | 1 |
Nr Exposed | 8 |
Gravity | 10 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19101200 G08 |
Issuance Date | 2011-04-15 |
Abatement Due Date | 2011-04-20 |
Nr Instances | 1 |
Nr Exposed | 8 |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2011-04-15 |
Abatement Due Date | 2011-04-20 |
Nr Instances | 1 |
Nr Exposed | 8 |
Date of last update: 02 Feb 2025