Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-11-06
|
Emphasis |
N: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1744762 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260102 A01 |
Issuance Date |
2024-11-15 |
Abatement Due Date |
2024-12-02 |
Current Penalty |
5531.0 |
Initial Penalty |
5531.0 |
Final Order |
2025-01-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: a) At 1844 Sunset Maple Road, Lot 14B Pecan Valley, Cantonment, Florida: On November 6, 2024; the employer allowed his employees to operate pneumatic nail guns without eye protection while performing roofing activities exposing his employees to struck-by hazards. The Jose Salas dba Jose Salas was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102 (a)(1), which was contained in OSHA inspection number 1744762, citation number 1, item number 1 and was affirmed as a final order on July 10, 2024, with respect to a workplace located at 4107 - 4135 Pendragon Circle. Lot 15D - 22 D Lancelot Town Homes, Milton, Florida. |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-11-15 |
Abatement Due Date |
2024-12-02 |
Current Penalty |
8297.0 |
Initial Penalty |
8297.0 |
Final Order |
2025-01-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 1844 Sunset Maple Road, Lot 14B Pecan Valley, Cantonment, Florida: On November 6, 2024; the employer allowed his employees to perform roofing activities without fall protection exposing his employees to a fall hazard of 11 feet 11 inches to the ground below. The Jose Salas dba Jose Salas was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(13), which was contained in OSHA inspection number 1744762, citation number 1, item number 2 and was affirmed as a final order on July 10, 2024, with respect to a workplace located at 4107 - 4135 Pendragon Circle. Lot 15D - 22 D Lancelot Town Homes, Milton, Florida. |
|
Citation ID |
01003 |
Citaton Type |
Repeat |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-11-15 |
Abatement Due Date |
2024-12-02 |
Current Penalty |
5531.0 |
Initial Penalty |
5531.0 |
Final Order |
2025-01-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed: a) At 1844 Sunset Maple Road, Lot 14B Pecan Valley, Cantonment, Florida: On November 6, 2024; the employer allowed his employees to use an extension ladder to access the roof of a residential house and the rails of the ladder did not extend three feet above the roof landing to provide safe access exposing his employees to a fall hazard of 10 feet 2 inches to the ground below. The Jose Salas dba Jose Salas was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053 (b)(1), which was contained in OSHA inspection number 1744762, citation number 1, item number 3 and was affirmed as a final order on July 10, 2024, with respect to a workplace located at 4107 - 4135 Pendragon Circle. Lot 15D - 22 D Lancelot Town Homes, Milton, Florida. |
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-04-30
|
Emphasis |
N: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2024-05-08 |
Current Penalty |
2765.0 |
Initial Penalty |
2765.0 |
Final Order |
2024-07-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: a) At 4107 - 4135 Pendragon Circle, Units 15D - 22D Lancelot Townhomes, Milton, Florida: On April 30, 2024; the employer allowed his employees to operate pneumatic nail guns without eye protection while performing roofing activities exposing his employees to struck-by hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-05-08 |
Abatement Due Date |
2024-05-22 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-07-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 4107 - 4135 Pendragon Circle, Units 15D - 22D Lancelot Townhomes, Milton, Florida: On April 30, 2024; the employer allowed his employees to perform roofing activities without fall protection exposing his employees to a fall hazard of 22 feet to the ground below. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-05-08 |
Current Penalty |
3457.0 |
Initial Penalty |
3457.0 |
Final Order |
2024-07-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At 4107 - 4135 Pendragon Circle, Units 15D - 22D Lancelot Townhomes, Milton, Florida: On April 30, 2024; the employer allowed his employees to use an extension ladder to gain access to the roof and the rails of the ladder did not extend at least three feet above the roof landing to provide safe access exposing his employees to a fall hazard of 17 feet 11 inches to the ground below. |
|
|