Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-04-04
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2020-10-20
|
Related Activity
Type |
Inspection |
Activity Nr |
1222929 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1222938 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2017-07-14 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-10-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold not fully planked. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2017-07-14 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-10-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without base plates. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2017-07-14 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-10-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without and access ladder. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 F04 |
Issuance Date |
2017-07-14 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-10-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold with bended bracing. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2017-07-14 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-10-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without guardrails. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260451 H02 II |
Issuance Date |
2017-07-14 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
4346.0 |
Initial Penalty |
4346.0 |
Final Order |
2017-10-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without toaboards. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2017-07-14 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-10-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold with missing bracing. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2017-07-14 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-10-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 4/04/2016, at the above addressed jobsite, employees were engaged in roofing operations at 21 feet, 3 inches from ground level without a means of fall protection. |
|
|