Search icon

VCM CONSTRUCTION INC. - Florida Company Profile

Company Details

Entity Name: VCM CONSTRUCTION INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

VCM CONSTRUCTION INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 06 May 2008 (17 years ago)
Last Event: AMENDMENT
Event Date Filed: 19 Jun 2008 (17 years ago)
Document Number: P08000045393
FEI/EIN Number 262271108

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2404 Hollywood Blvd, Hollywood, FL, 33020, US
Mail Address: 2404 Hollywood Blvd, Hollywood, FL, 33020, US
ZIP code: 33020
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
VERZURA ANDREW K Director 2404 Hollywood Blvd, Hollywood, FL, 33020
MACKEN ALAN S Director 2404 Hollywood Blvd, Hollywood, FL, 33020
Toro Ferdinand Agent 2404 Hollywood Blvd, Hollywood, FL, 33020

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G18000050807 VCM BUILDERS, INC. ACTIVE 2018-04-23 2028-12-31 - 2404 HOLLYWOOD BLVD, HOLLYWOOD, FL, 33020
G14000019760 VCM BUILDERS INC. ACTIVE 2014-02-25 2029-12-31 - 2404 HOLLYWOOD BLVD, HOLLYWOOD, FL, 33020

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2022-04-12 2404 Hollywood Blvd, Hollywood, FL 33020 -
CHANGE OF MAILING ADDRESS 2022-04-12 2404 Hollywood Blvd, Hollywood, FL 33020 -
REGISTERED AGENT ADDRESS CHANGED 2022-04-12 2404 Hollywood Blvd, Hollywood, FL 33020 -
REGISTERED AGENT NAME CHANGED 2018-04-09 Toro, Ferdinand -
AMENDMENT 2008-06-19 - -

Documents

Name Date
ANNUAL REPORT 2024-02-05
ANNUAL REPORT 2023-01-17
ANNUAL REPORT 2022-04-12
ANNUAL REPORT 2021-03-16
ANNUAL REPORT 2020-06-11
ANNUAL REPORT 2019-04-09
ANNUAL REPORT 2018-04-09
ANNUAL REPORT 2017-04-25
ANNUAL REPORT 2016-03-30
ANNUAL REPORT 2015-02-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342229341 0418800 2017-04-04 307 SEVEN ISLES DRIVE, FORT LAUDERDALE, FL, 33301
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-04-04
Emphasis P: FALL, L: FALL
Case Closed 2020-10-20

Related Activity

Type Inspection
Activity Nr 1222929
Safety Yes
Type Inspection
Activity Nr 1222938
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2017-07-14
Abatement Due Date 2017-07-26
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2017-10-10
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold not fully planked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2017-07-14
Abatement Due Date 2017-07-26
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2017-10-10
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without base plates.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2017-07-14
Abatement Due Date 2017-07-26
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2017-10-10
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without and access ladder.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 F04
Issuance Date 2017-07-14
Abatement Due Date 2017-07-26
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2017-10-10
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold with bended bracing.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2017-07-14
Abatement Due Date 2017-07-26
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2017-10-10
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without guardrails.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 H02 II
Issuance Date 2017-07-14
Abatement Due Date 2017-07-26
Current Penalty 4346.0
Initial Penalty 4346.0
Final Order 2017-10-10
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without toaboards.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2017-07-14
Abatement Due Date 2017-07-26
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2017-10-10
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about 4/04/2016, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold with missing bracing.
Citation ID 01008
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-07-14
Abatement Due Date 2017-07-26
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2017-10-10
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 4/04/2016, at the above addressed jobsite, employees were engaged in roofing operations at 21 feet, 3 inches from ground level without a means of fall protection.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
3747457209 2020-04-27 0455 PPP 17071 W Dixie Hwy, North Miami Beach, FL, 33160-3773
Loan Status Date 2022-02-24
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 89800
Loan Approval Amount (current) 89800
Undisbursed Amount 0
Franchise Name -
Lender Location ID 17616
Servicing Lender Name Seacoast National Bank
Servicing Lender Address 815 Colorado Ave, STUART, FL, 34994-3053
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address North Miami Beach, MIAMI-DADE, FL, 33160-3773
Project Congressional District FL-24
Number of Employees 8
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 458637
Originating Lender Name Seacoast National Bank
Originating Lender Address Coral Gables, FL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 90767.84
Forgiveness Paid Date 2021-05-28

Date of last update: 01 Apr 2025

Sources: Florida Department of State