Search icon

AOA ELECTRIC,INC. - Florida Company Profile

Company Details

Entity Name: AOA ELECTRIC,INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

AOA ELECTRIC,INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 15 Apr 2008 (17 years ago)
Date of dissolution: 16 Dec 2022 (2 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 16 Dec 2022 (2 years ago)
Document Number: P08000038138
FEI/EIN Number 262381505

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 605 PALMETTO DR, MASCOTTE, FL, 34753
Mail Address: 605 PALMETTO DR, MASCOTTE, FL, 34753
ZIP code: 34753
County: Lake
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ALVAREZ ALVARO President 605 PALMETTO DR, MASCOTTE, FL, 34753
ALVAREZ ALVARO O Agent 605 PALMETTO DR, MASCOTTE, FL, 34753

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2022-12-16 - -
REINSTATEMENT 2011-03-22 - -
CHANGE OF PRINCIPAL ADDRESS 2011-03-22 605 PALMETTO DR, MASCOTTE, FL 34753 -
CHANGE OF MAILING ADDRESS 2011-03-22 605 PALMETTO DR, MASCOTTE, FL 34753 -
REGISTERED AGENT ADDRESS CHANGED 2011-03-22 605 PALMETTO DR, MASCOTTE, FL 34753 -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2010-09-24 - -

Documents

Name Date
VOLUNTARY DISSOLUTION 2022-12-16
ANNUAL REPORT 2022-04-25
ANNUAL REPORT 2021-04-30
ANNUAL REPORT 2020-02-06
ANNUAL REPORT 2019-04-09
ANNUAL REPORT 2018-01-15
ANNUAL REPORT 2017-01-21
ANNUAL REPORT 2016-03-07
ANNUAL REPORT 2015-01-09
ANNUAL REPORT 2014-01-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337971634 0419700 2012-12-20 3209 SOUTH ATLANTIC, DAYTONA BEACH SHORES, FL, 32116
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-12-20
Emphasis L: FALL, P: FALL
Case Closed 2013-11-27

Related Activity

Type Inspection
Activity Nr 797122
Safety Yes
Type Inspection
Activity Nr 797301
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-01-02
Abatement Due Date 2013-01-29
Current Penalty 1500.0
Initial Penalty 2975.0
Final Order 2013-01-25
Nr Instances 4
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about December 20, 2012, on the north side of the 1st, 2nd, 3rd, and 4th floors, employees were using stairs near an unprotected edge and were not protected from a 32 feet fall hazard, by the use of a fall protection system.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2013-01-02
Abatement Due Date 2013-01-29
Current Penalty 1200.0
Initial Penalty 2380.0
Final Order 2013-01-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a. On or about December 20, 2012, on the north side of the 3rd floor, employees were working near floor holes that were not covered, exposing themselves to a trip hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2013-01-02
Abatement Due Date 2013-01-29
Current Penalty 1500.0
Initial Penalty 2975.0
Final Order 2013-01-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: a. On or about December 20, 2012, on the north side, the stairs leading from the 1st to the 2nd floor did not have a stair rail along an unprotected side.