343940920
|
0418800
|
2019-04-16
|
650 SNUG HARBOR DR., BOYNTON BEACH, FL, 33435
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-04-16
|
Case Closed |
2021-01-25
|
Related Activity
Type |
Referral |
Activity Nr |
1446183 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2019-09-27 |
Current Penalty |
1989.4 |
Initial Penalty |
2842.0 |
Final Order |
2019-10-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about 04/16/2019, at the 650 Snug Harbor Dr. Boynton Beach, FL 33435 jobsite, the employer did not develop and implement a hazard communication program while employees used chemicals such as but not limited to Aquafin Rebar Primer exposing them to a chemical hazard. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2019-09-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-10-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: On or about 04/16/2019, at the 650 Snug Harbor Dr. Boynton Beach, FL 33435 jobsite, the employer did not have a safety data sheet for chemicals used such as but not limited to Aquafin Rebar Primer (pH=11-13.5) exposing them to a chemical hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2019-09-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-10-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): 29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, who wear respirators when such use was not required by the employer: On or about 04/16/2019, at the 650 Snug Harbor Dr. Boynton Beach, FL 33435 jobsite, employees who wore a 3M filtering facepiece respirator had not received the information contained in the appendix D of the standard as required. |
|
|
343922605
|
0418800
|
2019-04-10
|
650 SNUG HARBOR DR UNIT#G210, BOYNTON BEACH, FL, 33424
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-04-10
|
Emphasis |
L: FALL
|
Case Closed |
2023-04-13
|
Related Activity
Type |
Referral |
Activity Nr |
1444713 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 A02 |
Issuance Date |
2019-09-27 |
Abatement Due Date |
2019-10-24 |
Current Penalty |
3712.8 |
Initial Penalty |
5304.0 |
Final Order |
2019-10-08 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work had the strength and structural integrity to support employees safely: On or about 04/10/2019, Location: 650 Snug Harbor Dr. Apartment units #G210 and G209 Boynton Beach FL 33424, 1) Employees were exposed to fall hazards while working on balconies under renovation prior and during demolition activities without determining structural integrity and without adequate shoring/support being provided. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260701 A |
Issuance Date |
2019-09-27 |
Abatement Due Date |
2019-10-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-10-08 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.701(a): Construction loads were placed on a concrete structure or portion of a concrete structure without the employer having determined, based on information received from a person who was qualified in structural design, that the structure or portion of the structure is capable of supporting the loads: On or about 04/10/2019, Location: 650 Snug Harbor Dr. Apartment units #G210 and G209 Boynton Beach FL 33424, 1) Employees were exposed to fall hazards while installing shoring and using chipping hammers on the upper surfaces of balconies that were under renovation prior to determining if the structure was capable of supporting the applied loads. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2019-09-27 |
Abatement Due Date |
2019-10-24 |
Current Penalty |
2121.7 |
Initial Penalty |
3031.0 |
Final Order |
2019-10-08 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii); On or about 04/10/2019, Location: 650 Snug Harbor Dr. Apartment Unit #G210 Boynton Beach FL 33424, 1) Employees were exposed to a fall hazard of approximately 9 ft to ground level, while working on scaffolds that were not fully planked. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2019-09-27 |
Abatement Due Date |
2019-10-24 |
Current Penalty |
2121.7 |
Initial Penalty |
3031.0 |
Final Order |
2019-10-08 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 04/10/2019, Location: 650 Snug Harbor Dr. Apartment Unit #G210 Boynton Beach FL 33424, 1) Employees were exposed to a fall hazard of approximately 9 ft to ground level, while working on a scaffold that was not provided with base plates, mud sills or other adequate firm foundation. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260502 D10 I |
Issuance Date |
2019-09-27 |
Abatement Due Date |
2019-10-24 |
Current Penalty |
3712.8 |
Initial Penalty |
5304.0 |
Final Order |
2019-10-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(10)(i): Except as provided in paragraph (d)(10)(ii) of this section, when vertical lifelines were used, each employee was not attached to a separate lifeline: On or about 04/10/2019, Location: 650 Snug Harbor Dr. Apartment Unit #G210 Boynton Beach FL 33424, 1) Two employees were exposed to a fall hazard of approximately 9 ft to ground level, while working on a balcony undergoing renovation using a single vertical lifeline that was installed between two port shores. |
|
|
339474298
|
0418800
|
2013-11-05
|
1131 SE 4 STREET, BOYNTON BEACH, FL, 33436
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-11-05
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2014-05-09
|
Related Activity
Type |
Complaint |
Activity Nr |
860957 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2014-04-23 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-05-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about, November 05, 2013 at the above addressed jobsite, employees were exposed to a fall hazard as they worked from a balcony without using fall protection. |
|
|