Search icon

ALL AMERICAN GROUP CONTRACTORS, INC. - Florida Company Profile

Company Details

Entity Name: ALL AMERICAN GROUP CONTRACTORS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ALL AMERICAN GROUP CONTRACTORS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 26 Nov 2007 (17 years ago)
Date of dissolution: 24 Sep 2021 (3 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 24 Sep 2021 (3 years ago)
Document Number: P07000125840
FEI/EIN Number 261455364

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1021 MANDALAY DRIVE, BRANDON, FL, 33511, US
Mail Address: 1021 MANDALAY DRIVE, BRANDON, FL, 33511, US
ZIP code: 33511
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
HOLT Juanita President 1021 MANDALAY DRIVE, BRANDON, FL, 33511
HOLT JUANITA Agent 1021 MANDALAY DRIVE, BRANDON, FL, 33511

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -
REGISTERED AGENT NAME CHANGED 2019-04-22 HOLT, JUANITA -

Documents

Name Date
ANNUAL REPORT 2020-06-23
ANNUAL REPORT 2019-04-22
ANNUAL REPORT 2018-02-16
ANNUAL REPORT 2017-04-06
ANNUAL REPORT 2016-04-30
ANNUAL REPORT 2015-02-24
AMENDED ANNUAL REPORT 2014-05-13
ANNUAL REPORT 2014-01-27
ANNUAL REPORT 2013-04-29
ANNUAL REPORT 2012-04-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341006062 0420600 2015-10-20 29612 EAGLE STATION DR, WESLEY CHAPEL, FL, 33543
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-10-20
Emphasis P: FALL, L: EISAOF, L: EISAX, L: FALL
Case Closed 2015-12-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-10-29
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-11-30
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 29 CFR 1926.501(b): a. During residential roofing work, employees were exposed to a fall hazard 8 feet six inches, in that, four employees were stripping and installing roofing shingles without any type of fall protection, on or about 10/20/2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-10-29
Abatement Due Date 2015-12-03
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-11-30
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. During residential roofing work, employees exposed to a fall hazard were not provided training and education relating to fall protection, hazard recognition, procedures to be followed to minimize these hazards and the proper use and limitations of fall protection equipment and fall protection systems, on or about 10/20/2015.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2015-10-29
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-11-30
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. During residential roofing work, employees were exposed to a fall hazard 8 feet 6 inches, in that, an extension ladder used to gain access to the roof extended 2 feet 6 inches from the landing surface, on or about 10/20/2015.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2015-10-29
Abatement Due Date 2015-12-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-11-30
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. The employer did not develop and implement a safety and health program to address the company policy on safety as well as the employer/employee responsibilities, on or about 10/20/2015.