Entity Name: | T PRO CONSTRUCTION, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
T PRO CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 09 Oct 2007 (18 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 10 Dec 2019 (5 years ago) |
Document Number: | P07000111231 |
FEI/EIN Number |
261131975
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 601 Southwest Park Street, OKEECHOBEE, FL, 34974, US |
Mail Address: | 601 Southwest Park Street, OKEECHOBEE, FL, 34974, US |
ZIP code: | 34974 |
County: | Okeechobee |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
TYSON JOHN | Agent | 601 Southwest Park Street, OKEECHOBEE, FL, 34974 |
TYSON JOHN | President | 2457 SW 33RD CIRCLE, OKEECOHBEE, FL, 34974 |
TYSON JOHN | Secretary | 2457 SW 33RD CIRCLE, OKEECOHBEE, FL, 34974 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2023-02-27 | 601 Southwest Park Street, OKEECHOBEE, FL 34974 | - |
CHANGE OF MAILING ADDRESS | 2023-02-27 | 601 Southwest Park Street, OKEECHOBEE, FL 34974 | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-02-27 | 601 Southwest Park Street, OKEECHOBEE, FL 34974 | - |
AMENDMENT | 2019-12-10 | - | - |
REGISTERED AGENT NAME CHANGED | 2019-12-10 | TYSON, JOHN | - |
NAME CHANGE AMENDMENT | 2009-06-15 | T PRO CONSTRUCTION, INC. | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-03-07 |
ANNUAL REPORT | 2023-02-27 |
ANNUAL REPORT | 2022-04-25 |
ANNUAL REPORT | 2021-04-07 |
ANNUAL REPORT | 2020-03-18 |
Amendment | 2019-12-10 |
ANNUAL REPORT | 2019-04-02 |
ANNUAL REPORT | 2018-04-04 |
ANNUAL REPORT | 2017-04-13 |
ANNUAL REPORT | 2016-03-11 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341411924 | 0418800 | 2016-04-19 | 1151 SE INDIAN STREET, STUART, FL, 34997 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2016-05-16 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2016-07-08 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about April 19, 2016, at the above addressed site, employees were expose to fall hazard of approximately 12 feet 6 inches when performing carpentry work on the roof of a building while not being protected from falling to the lower level. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2016-05-16 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2016-07-08 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about April 19, 2016, at the above addressed site, employees were exposed to a fall hazard when using an extension ladder to gain access to a roof approximately 12 feet 6 inches in height while the ladder did not extend at least 3 feet past the upper landing surface. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B08 |
Issuance Date | 2016-05-16 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2016-07-08 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: On or about April 19, 2016, at the above addressed site, employees were exposed to a fall hazard when using an extension ladder to gain access to a roof approximately 12 feet 6 inches that set up on an active construction site and was not secured to prevent accidental displacement. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2014-09-18 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2014-11-14 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2014-10-28 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-11-13 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: On or about September 18, 2014, at the above addressed site, employees were exposed to a fall hazard of approximately 10 feet 6 inches when performing carpentry work from the basket of an aerial lift while not wearing a harness with a lanyard attached to the boom or basket of that lift. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2014-10-28 |
Abatement Due Date | 2014-11-03 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-11-13 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On or about September 18, 2014, at the above addressed site, employees exposed to a fall hazard when using an aerial lift when performing carpentry work were not provided with a training program that would enable them to recognize the hazards associated with using that lift. |