Entity Name: | DON SIGNS, INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
DON SIGNS, INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 17 May 2007 (18 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 11 May 2015 (10 years ago) |
Document Number: | P07000059375 |
FEI/EIN Number |
260195220
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5250 BTC PLACE, KISSIMMEE, FL, 34758 |
Mail Address: | 5250 BTC PLACE, KISSIMMEE, FL, 34758 |
ZIP code: | 34758 |
County: | Osceola |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
MEDINA JULIO | President | 5250 BTC PLACE, KISSIMMEE, FL, 34758 |
MEDINA JULIO | Director | 5250 BTC PLACE, KISSIMMEE, FL, 34758 |
MEDINA JULIO | Treasurer | 5250 BTC PLACE, KISSIMMEE, FL, 34758 |
MEDINA JULIO Jr. | Vice President | 5250 BTC PLACE, KISSIMMEE, FL, 34758 |
MEDINA AMY | Treasurer | 5250 BTC PLACE, KISSIMMEE, FL, 34758 |
MEDINA JULIO | Agent | 5250 BTC PLACE, KISSIMMEE, FL, 34758 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
AMENDMENT | 2015-05-11 | - | - |
REGISTERED AGENT NAME CHANGED | 2011-04-29 | MEDINA, JULIO | - |
REGISTERED AGENT ADDRESS CHANGED | 2008-03-14 | 5250 BTC PLACE, KISSIMMEE, FL 34758 | - |
CHANGE OF PRINCIPAL ADDRESS | 2007-09-11 | 5250 BTC PLACE, KISSIMMEE, FL 34758 | - |
CHANGE OF MAILING ADDRESS | 2007-09-11 | 5250 BTC PLACE, KISSIMMEE, FL 34758 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-05 |
ANNUAL REPORT | 2023-03-27 |
ANNUAL REPORT | 2022-02-14 |
ANNUAL REPORT | 2021-01-29 |
ANNUAL REPORT | 2020-01-21 |
ANNUAL REPORT | 2019-02-15 |
ANNUAL REPORT | 2018-03-12 |
ANNUAL REPORT | 2017-03-16 |
ANNUAL REPORT | 2016-01-18 |
Amendment | 2015-05-11 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346914104 | 0420600 | 2023-08-16 | 5250 BTC PLACE, KISSIMMEE, FL, 34758 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 2067856 |
Safety | Yes |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2019-08-20 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2020-05-18 |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260503 A02 |
Issuance Date | 2020-02-11 |
Abatement Due Date | 2020-03-09 |
Current Penalty | 1590.5 |
Initial Penalty | 3181.0 |
Final Order | 2020-03-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a. On or about August 20, 2019, at the jobsite, untrained employees were wearing safety harnesses while working from an aerial lift and they did not understand how to properly wear and use the personal fall protection equipment at the jobsite. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260502 D01 |
Issuance Date | 2020-02-11 |
Abatement Due Date | 2020-03-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-03-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials: a. On or about August 20, 2019, at the jobsite, the safety lanyard attached to one employee's safety harnesses was secured to the back portion of the harness using a knot and another strap. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260502 D21 |
Issuance Date | 2020-02-11 |
Abatement Due Date | 2020-03-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-03-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a. On or about August 20, 2019, at the jobsite, the personal fall arrest equipment used by employees working from an aerial lift was not inspected prior to use. |
Citation ID | 02001 |
Citaton Type | Repeat |
Standard Cited | 19260453 B02 V |
Issuance Date | 2020-02-11 |
Current Penalty | 3181.0 |
Initial Penalty | 6362.0 |
Final Order | 2020-03-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. On or about August 20, 2019, at the jobsite, employees were exposed to an ejection hazard when using a truck mount aerial lift. The employees were installing letters of a sign along the exterior of a commercial building and the safety lanyards attached to safety harness employees were wearing were not connected to anchor points. Don Signs, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.453(b)(2)(v), which was contained in OSHA inspection number 1249572, citation number 1, item number 2 and was affirmed as a final order on August 3, 2017, with respect to a workplace located at 7900 US Hwy 19, Pinellas Park, FL 33780. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-07-25 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2019-02-11 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 IV |
Issuance Date | 2017-08-03 |
Current Penalty | 2281.8 |
Initial Penalty | 3803.0 |
Final Order | 2017-08-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: a. At the site, an employee was exposed to a 40 feet fall hazard when using a JLG T500J aerial lift during sign construction at the exterior of a building, in that, during progress of work the employee was witnessed standing on the railings of the basket, on or about 07/25/2017. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2017-08-03 |
Current Penalty | 2281.8 |
Initial Penalty | 3803.0 |
Final Order | 2017-08-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: (Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated.) a. At the site, employees were exposed to a 40 feet fall hazard when using a JLG T500J aerial lift during construction of a sign at the exterior of a building without the use of a fall arrest system such as a full body harness or a body belt used as a restraint system, on or about 07/25/2017. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260020 B01 |
Issuance Date | 2017-08-03 |
Abatement Due Date | 2017-09-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-08-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. The employer did not develop and implement a safety and health program to address the company policy on safety as well as the employer/employee responsibilities, on or about 07/25/2017. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6101347706 | 2020-05-01 | 0455 | PPP | 5250 BTC PL, KISSIMMEE, FL, 34758-2051 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 02 Apr 2025
Sources: Florida Department of State