Entity Name: | GOLDEN ROOFING, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
GOLDEN ROOFING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 01 May 2007 (18 years ago) |
Date of dissolution: | 26 Sep 2014 (11 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 26 Sep 2014 (11 years ago) |
Document Number: | P07000052309 |
FEI/EIN Number |
208941513
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2036 SEA HAWK CIRCLE, PONTE VEDRA, FL, 32082 |
Mail Address: | 2036 SEA HAWK CIRCLE, PONTE VEDRA, FL, 32082 |
ZIP code: | 32082 |
County: | St. Johns |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
YANCEY MICHAEL D | President | 2036 SEA HAWK CIRCLE, PONTE VEDRA, FL, 32082 |
FOSTER JAMES J | Agent | 185 BAY TREE DRIVE, MIRAMAR BEACH, FL, 32550 |
YANCEY MICHAEL D | Secretary | 2036 SEA HAWK CIRCLE, PONTE VEDRA, FL, 32082 |
YANCEY MICHAEL D | Treasurer | 2036 SEA HAWK CIRCLE, PONTE VEDRA, FL, 32082 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2014-09-26 | - | - |
CHANGE OF MAILING ADDRESS | 2010-04-12 | 2036 SEA HAWK CIRCLE, PONTE VEDRA, FL 32082 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2013-05-06 |
ANNUAL REPORT | 2012-04-30 |
ANNUAL REPORT | 2011-04-25 |
ANNUAL REPORT | 2010-04-12 |
ANNUAL REPORT | 2009-04-13 |
ANNUAL REPORT | 2008-04-22 |
Domestic Profit | 2007-05-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
334815784 | 0419700 | 2012-06-20 | 9685 BAYOU BLUFF ROAD, JACKSONVILLE, FL, 32256 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2012-08-15 |
Current Penalty | 1360.0 |
Initial Penalty | 1360.0 |
Final Order | 2012-09-10 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a. On or about June 20, 2012, two employees using Hitachi NV45AB2 pneumatic air nail guns did not have on safety glasses, exposing themselves to being hit by nails or flying debris. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2012-08-15 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-09-10 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure: a. On or about June 20, 2012, on a 6:12 pitch roof, two employees performing roofing operations were not protected from an 8 foot fall hazard by use of a guardrail system, safety net system or personal fall arrest system, or any alternative fall protection. |
Date of last update: 03 Apr 2025
Sources: Florida Department of State