Search icon

BELQUETTE INC. - Florida Company Profile

Company Details

Entity Name: BELQUETTE INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

BELQUETTE INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 29 Mar 2007 (18 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P07000040021
FEI/EIN Number 450547333

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3634 131ST AVENUE N, CLEARWATER, FL, 33762
Mail Address: 3634 131ST AVENUE N, CLEARWATER, FL, 33762
ZIP code: 33762
County: Pinellas
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
WEIBEL BRETT President 8694 OAKDALE DR, SEMINOLE, FL, 33777
MOMBOURQUETTE MARK Director 3634 131ST AVE N, CLEARWATER, FL, 33762
WEIBEL BRETT D Agent 8694 OAKDALE DR, SEMINOLE, FL, 33777

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2012-01-17 3634 131ST AVENUE N, CLEARWATER, FL 33762 -
CHANGE OF MAILING ADDRESS 2012-01-17 3634 131ST AVENUE N, CLEARWATER, FL 33762 -
REGISTERED AGENT ADDRESS CHANGED 2012-01-17 8694 OAKDALE DR, SEMINOLE, FL 33777 -
REGISTERED AGENT NAME CHANGED 2011-02-17 WEIBEL, BRETT D -

Documents

Name Date
ANNUAL REPORT 2018-03-12
ANNUAL REPORT 2017-01-19
ANNUAL REPORT 2016-02-18
ANNUAL REPORT 2015-01-05
ANNUAL REPORT 2014-01-28
ANNUAL REPORT 2013-03-26
ANNUAL REPORT 2012-01-17
ANNUAL REPORT 2011-02-17
ANNUAL REPORT 2010-02-17
ANNUAL REPORT 2009-04-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340183698 0420600 2015-01-15 3634 131ST AVENUE NORTH, CLEARWATER, FL, 33762
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2015-01-15
Emphasis L: EISAOF, L: EISAX, L: FORKLIFT
Case Closed 2015-02-26

Related Activity

Type Complaint
Activity Nr 931446
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 2015-02-10
Abatement Due Date 2015-03-09
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Ink Room - No eyewash was provided where cleaners containing alkalines were used, on or about January 15, 2015.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2015-02-10
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Cut Room - Central Machinery 6" bench grinder, number 37822, work rest on the right side was 5/16" from the wheel, on or about January 15, 2015.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2015-02-10
Abatement Due Date 2015-02-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Cut Room - Central Machinery 6" bench grinder, number 37822, was missing the tongue guard, on or about January 15, 2015.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2015-02-10
Abatement Due Date 2015-03-09
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Facility-wide - There was no written hazard communication program in place, on or about January 15, 2015. Chemicals used included 2-methoxymethylethoxy propanol, propylene glycol, ethylene glycol, and hydrocracked and hydrotreated paraffinic oils.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101200 F05
Issuance Date 2015-02-10
Abatement Due Date 2015-02-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: a) Ink Room - Secondary bottles of chemicals, including but not limited to, inks, cleaning solutions and vacuum pump oil were not provided with labels, on or about January 15, 2015.
Citation ID 02001
Citaton Type Other
Standard Cited 19100303 G01
Issuance Date 2015-02-10
Abatement Due Date 2015-02-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Pre-treat Room - There were containers on the floor in front of the electrical panels, on or about January 15, 2015.