Search icon

DONE RITE ROOFING INC. - Florida Company Profile

Company Details

Entity Name: DONE RITE ROOFING INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

DONE RITE ROOFING INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 23 Feb 2007 (18 years ago)
Document Number: P07000025614
FEI/EIN Number 208522365

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 211 HEDDEN COURT, PALM HARBOR, FL, 34683, US
Mail Address: 211 HEDDEN COURT, PALM HARBOR, FL, 34683, US
ZIP code: 34683
County: Pinellas
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Loiacano Christina President 211 HEDDEN COURT, Palm Harbor, FL, 34683
Freidinger Ted Agent 34921 US 19 Suite 150, PALM HARBOR, FL, 34684

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2022-04-11 211 HEDDEN COURT, PALM HARBOR, FL 34683 -
CHANGE OF MAILING ADDRESS 2022-04-11 211 HEDDEN COURT, PALM HARBOR, FL 34683 -
REGISTERED AGENT NAME CHANGED 2019-03-19 Freidinger, Ted -
REGISTERED AGENT ADDRESS CHANGED 2019-03-19 34921 US 19 Suite 150, PALM HARBOR, FL 34684 -

Documents

Name Date
ANNUAL REPORT 2024-03-27
ANNUAL REPORT 2023-03-28
ANNUAL REPORT 2022-04-11
ANNUAL REPORT 2021-01-28
ANNUAL REPORT 2020-04-03
ANNUAL REPORT 2019-03-19
ANNUAL REPORT 2018-01-12
ANNUAL REPORT 2017-01-09
ANNUAL REPORT 2016-01-18
ANNUAL REPORT 2015-01-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346639800 0420600 2023-04-18 835 SHADY OAKS PLACE, PALM HARBOR, FL, 34684
Inspection Type Complaint
Scope NoInspection
Safety/Health Safety
Close Conference 2023-04-18
Emphasis L: FALL
Case Closed 2023-04-20

Related Activity

Type Complaint
Activity Nr 2021428
Safety Yes
344422480 0420600 2019-10-25 702 GUISANDO DE AVILA, TAMPA, FL, 33613
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2019-10-25
Emphasis L: FALL
Case Closed 2020-05-19

Related Activity

Type Referral
Activity Nr 1508517
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2020-04-23
Abatement Due Date 2020-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-05-19
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) At the inspection site, on or about October 25, 2019, the employer did not have a written certification record in fall protection training for employees installing roof tiles on a one-story 5:12 pitch residential dwelling with ground to eave heights varying from 8 to 12 feet.
340934561 0420600 2015-09-22 340 4TH STREET S., SAINT PETERSBURG, FL, 33710
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-09-22
Emphasis L: FALL, P: FALL
Case Closed 2018-05-24

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B08
Issuance Date 2015-12-09
Current Penalty 3234.0
Initial Penalty 5390.0
Final Order 2016-01-12
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: a. At the jobsite, the portable extension ladder used to access the 2nd story porch roof was not secured from displacement, exposing employees to a 25 foot fall hazard, on or about 9/22/15.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2015-12-09
Current Penalty 32340.0
Initial Penalty 53900.0
Final Order 2016-01-12
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the 2nd story porch roof, fall protection was not provided, exposing employees to a 25 foot fall hazard, on or about 9/22/15.
339297871 0420600 2013-08-14 39780 US HIGHWAY 19 N., TARPON SPRINGS, FL, 34689
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-08-14
Emphasis L: FALL, P: FALL
Case Closed 2014-02-13

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19261053 B01
Issuance Date 2013-08-27
Current Penalty 154.0
Initial Penalty 154.0
Final Order 2013-09-23
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. Southeast side of building - employees were exposed to a 7'-7" fall hazard, in that, the ladder side rails extended 33" above the roof landing. Violation observed on or about 8/14/13. Done Rite Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.10531(b)(1), which was contained in OSHA inspection number 899046, citation number 1, item number 2, and was affirmed as final order on 05/28/13, with respect to a workplace located on 304 Buckingham Place, Palm Harbor, FL 34684.
Citation ID 01002
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2013-08-27
Abatement Due Date 2013-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. At the site - the employer did not develop a written training certification for employees exposed a 7'-7" fall hazard while working on a 4 in 12 pitched roof. Violation observed on or about 08/14/13.
338990468 0420600 2013-04-04 304 BUCKINGHAM PL,, PALM HARBOR, FL, 34684
Inspection Type Prog Related
Scope Partial
Safety/Health Health
Close Conference 2013-04-04
Emphasis P: FALL, L: FALL
Case Closed 2013-11-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-05-15
Abatement Due Date 2013-05-21
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2013-05-28
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a)At the site, employees, tearing off roofing shingles were exposed to a 18 foot high fall hazard. without fall protection. Employees were not protected from fall hazard(s).
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-05-15
Abatement Due Date 2013-05-15
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2013-05-28
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) At the site employees are exposed to a 8' high fall hazard when accessing the roof to conduct a tear off operation. Conditions were wet on this day.
316482793 0420600 2012-03-30 146 6TH AVENUE, ST. PETERSBURG, FL, 33701
Inspection Type Complaint
Scope NoInspection
Safety/Health Safety
Emphasis L: FALL
Case Closed 2012-04-11

Related Activity

Type Complaint
Activity Nr 208765487
Safety Yes
309833846 0420600 2006-02-28 KEYSTONE PRESBYTERIAN CHURCH/7509 VAN DYKE RD., LUTZ, FL, 33548
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2006-02-28
Emphasis L: FALL
Case Closed 2006-03-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2006-03-13
Abatement Due Date 2006-03-16
Current Penalty 1125.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 1
Gravity 10
309833689 0420600 2006-02-24 1614 KISMET CT., TARPON SPRINGS, FL, 34689
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2006-02-24
Emphasis L: FALL
Case Closed 2006-04-07

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2006-03-31
Abatement Due Date 2006-04-05
Current Penalty 1125.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 1
Gravity 10

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
5123177307 2020-04-30 0455 PPP 405 N ORANGE ST, PALM HARBOR, FL, 34683-5449
Loan Status Date 2021-03-05
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 293748
Loan Approval Amount (current) 293748
Undisbursed Amount 0
Franchise Name -
Lender Location ID 39334
Servicing Lender Name Trustmark National Bank
Servicing Lender Address 248 E Capitol St, JACKSON, MS, 39201-2503
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address PALM HARBOR, PINELLAS, FL, 34683-5449
Project Congressional District FL-13
Number of Employees 34
NAICS code 238160
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 39334
Originating Lender Name Trustmark National Bank
Originating Lender Address JACKSON, MS
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 295512.22
Forgiveness Paid Date 2021-02-12

Date of last update: 02 Apr 2025