Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-10-22
|
Emphasis |
L: EISAOF, L: EISAX, L: FALL, P: FALL
|
Case Closed |
2014-11-19
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2014-11-10 |
Abatement Due Date |
2014-11-18 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-11-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) For the jobsite at 38410 6th Ave., Zephyrhills, FL 33542, as observed on or about 10/22/2014, employees were working off of scaffolding that was not fully planked in sections. It was observed that the scaffolding was only 2/3 planked in areas employees were working. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2014-11-10 |
Abatement Due Date |
2014-11-21 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-11-17 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) For the jobsite at 38410 6th Ave., Zephyrhills, FL 33542, as observed on or about 10/22/2014, scaffolding footing erected in dirt/mud was not equipped with mud sills and was observed to sink into the dirt/mud. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2014-11-10 |
Abatement Due Date |
2014-11-21 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-11-17 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access: a) For the jobsite at 38410 6th Ave., Zephyrhills, FL 33542, as observed on or about 10/22/2014, scaffold access ladders were not available. Employees had to climb the scaffold frame to access the working level. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2014-11-10 |
Abatement Due Date |
2014-11-21 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-11-17 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) For the jobsite at 38410 6th Ave., Zephyrhills, FL 33542, as observed on or about 10/22/2014, employees were working off of an 11 ft. high scaffold and were not protected from falling by guardrails installed around all open edges or any other kind of fall protection. |
|
|