Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-08-15
|
Case Closed |
2016-10-27
|
Related Activity
Type |
Complaint |
Activity Nr |
1121525 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-10-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-10-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. a) For the establishment at 4401 West El Prado Blvd., as observed on or about 08/15/2016, compressed air guns were used for cleaning off parts to picture frames at dead front pressures of 80 p.s.i. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-10-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-10-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) For the facility at 4401 West El Prado Blvd., Tampa, FL 33609, as observed on or about 08/15/2016, a 110VAC panel box used to supply power to branched circuits was not labeled legibly in that all breakers were not clearly identified. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-10-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-10-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) For the facility at 4401 West El Prado Blvd., Tampa, FL 33609, as observed on or about 08/15/2016, a 110VAC electrical box was blocked by a musical instrument case, cardboard, and various items such that access to the box was inhibited. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-10-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-10-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) For the facility at 4401 West El Prado Blvd., Tampa, FL 33609, as observed on or about 08/15/2016, an extension cord was used to provide permanent power to a mini fridge, a microwave, and a coffee maker. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV C |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-10-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-10-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows or floors. a) For the facility at 4401 West El Prado Blvd., Tampa, FL 33609, as observed on or about 08/15/2016, an extension cord was run through a bathroom doorway. The extension cord was plugged in and used to power a microrowave, a mini-fridge, and a coffee maker that were located in another room. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-10-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-10-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a) For the facility at 4401 West El Prado Blvd., Tampa, FL 33629, as observed on or about 08/15/2016 In the picture frame cutting room where saws were present, the room was not kept in a clean condition in that wood dust had accumulation on the walls and upper surfaces. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-10-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) For the facility at 4401 West El Prado Blvd., Tampa, FL 33609, as observed on or about 08/15/2016, the employer did not ensure that employees who voluntarily used half-face cartridge respirators were medically able to use a respirator. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-09-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-10-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) For the facility at 4401 West El Prado Blvd., Tampa, FL 33609, as observed on or about 08/15/2016, employees who voluntarily used respirators were not provided with the information in appendix D of 29 CFR 1910.134. |
|
|