Search icon

FARRELL ROOFING INC - Florida Company Profile

Company Details

Entity Name: FARRELL ROOFING INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

FARRELL ROOFING INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 11 Sep 2006 (19 years ago)
Last Event: NAME CHANGE AMENDMENT
Event Date Filed: 18 Apr 2008 (17 years ago)
Document Number: P06000117399
FEI/EIN Number 205544908

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6835 COMMERCE AVE, PORT RICHEY, FL, 34668
Mail Address: PO BOX 776, PORT RICHEY, FL, 34673
ZIP code: 34668
County: Pasco
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
FARRELL STEPHEN J President 6835 COMMERCE AVE, PORT RICHEY, FL, 34668
FARRELL STEPHEN J Agent 6835 COMMERCE AVE, PORT RICHEY, FL, 34668

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2019-02-05 6835 COMMERCE AVE, PORT RICHEY, FL 34668 -
CHANGE OF PRINCIPAL ADDRESS 2012-01-06 6835 COMMERCE AVE, PORT RICHEY, FL 34668 -
CHANGE OF MAILING ADDRESS 2011-02-22 6835 COMMERCE AVE, PORT RICHEY, FL 34668 -
NAME CHANGE AMENDMENT 2008-04-18 FARRELL ROOFING INC -
REGISTERED AGENT NAME CHANGED 2007-04-28 FARRELL, STEPHEN J -

Documents

Name Date
ANNUAL REPORT 2024-02-07
ANNUAL REPORT 2023-03-06
ANNUAL REPORT 2022-02-01
ANNUAL REPORT 2021-02-01
ANNUAL REPORT 2020-01-28
ANNUAL REPORT 2019-02-05
ANNUAL REPORT 2018-04-02
ANNUAL REPORT 2017-03-13
ANNUAL REPORT 2016-01-25
ANNUAL REPORT 2015-01-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343882494 0420600 2019-03-26 10848 S.R. 54, NEW PORT RICHEY, FL, 34655
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2019-03-26
Emphasis L: FALL
Case Closed 2019-06-11

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2019-05-22
Current Penalty 3031.2
Initial Penalty 3789.0
Final Order 2019-06-11
Nr Instances 1
Nr Exposed 15
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about 03/26/2019, at the job site - the rails of the ladder used to access the second floor of the building did not extend at least 3 foot above the upper landing surface, exposing the employees to a 14 feet 5 inch fall hazard.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B10
Issuance Date 2019-05-22
Current Penalty 8486.4
Initial Penalty 10608.0
Final Order 2019-06-11
Nr Instances 1
Nr Exposed 15
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a. On or about 03/26/2019, at the job site - employees were exposed to 14 feet 9 inch and 14 feet 5 inch fall hazards while conducting roofing work, in that, fall protection was not used. FARRELL ROOFING INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(11), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1005057, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 02/24/2015, WITH RESPECT TO A WORKPLACE LOCATED AT 12830 SHADY HILLS ROAD SHADY HILLS, FL 34610.
Citation ID 03001
Citaton Type Other
Standard Cited 19040040 A
Issuance Date 2019-05-22
Current Penalty 606.4
Initial Penalty 758.0
Final Order 2019-06-11
Nr Instances 1
Nr Exposed 16
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours: a. On or about 03/26/2019, at the job site - On 03/26/2019 the employer was requested to provide OSHA 300 logs, but the employer failed to provide copies work-related injuries and illnesses or OSHA 300 log within 4 hours of request. Copies were provided on 03/27/2019, more than 24 hours after request.
Citation ID 03002
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2019-05-22
Abatement Due Date 2019-06-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-06-11
Nr Instances 1
Nr Exposed 15
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a. On or about 08/16/2018, at the job site - the employer did not provide a written certification of fall protection training records that contain the name or other identity of the employee trained, and the signature of the person who conducted the training or the signature of the employer.
341516045 0420600 2016-06-02 3933 WINSTON DR, NEW PORT RICHEY, FL, 34652
Inspection Type Complaint
Scope NoInspection
Safety/Health Safety
Close Conference 2016-06-02
Case Closed 2016-06-10

Related Activity

Type Complaint
Activity Nr 1097097
Safety Yes
340050574 0420600 2014-10-30 12830 SHADY HILLS RD, SHADY HILLS, FL, 34610
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-10-31
Emphasis L: FALL
Case Closed 2015-02-24

Related Activity

Type Complaint
Activity Nr 918421
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2014-11-06
Abatement Due Date 2014-11-13
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On the jobsite, employees were exposed to an approximate 14 ft fall hazard, in that, fall protection was not used while working from a 5 in 12 pitched roof. This violation was discovered on or about October 30, 2014.
339001794 0420600 2013-04-09 2555 ROYAL PINE CIRCLE, CLEARWATER, FL, 33763
Inspection Type Complaint
Scope NoInspection
Safety/Health Safety
Close Conference 2013-04-09
Emphasis L: FALL
Case Closed 2013-04-09

Related Activity

Type Complaint
Activity Nr 812608
Safety Yes

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
6774177305 2020-04-30 0455 PPP Po Box 776, Port Richey, FL, 34673
Loan Status Date 2021-07-30
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 281375.05
Loan Approval Amount (current) 281375.05
Undisbursed Amount 0
Franchise Name -
Lender Location ID 17652
Servicing Lender Name Capital City Bank
Servicing Lender Address 217 N Monroe St, TALLAHASSEE, FL, 32301-7619
Rural or Urban Indicator U
Hubzone N
LMI Y
Business Age Description Existing or more than 2 years old
Project Address Port Richey, PASCO, FL, 34673-0001
Project Congressional District FL-12
Number of Employees 33
NAICS code 238160
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 17652
Originating Lender Name Capital City Bank
Originating Lender Address TALLAHASSEE, FL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 284335.27
Forgiveness Paid Date 2021-05-27
1362168506 2021-02-18 0455 PPS 6835 Commerce Ave 6835 Commerce Ave, Port Richey, FL, 34668-6853
Loan Status Date 2022-03-12
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 287837
Loan Approval Amount (current) 287837
Undisbursed Amount 0
Franchise Name -
Lender Location ID 44449
Servicing Lender Name PNC Bank, National Association
Servicing Lender Address 222 Delaware Ave, WILMINGTON, DE, 19801-1621
Rural or Urban Indicator U
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address Port Richey, PASCO, FL, 34668-6853
Project Congressional District FL-12
Number of Employees 25
NAICS code 238160
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 44449
Originating Lender Name PNC Bank, National Association
Originating Lender Address WILMINGTON, DE
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 290555.46
Forgiveness Paid Date 2022-01-31

Date of last update: 03 Apr 2025

Sources: Florida Department of State