Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-05-25
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2016-07-20
|
Related Activity
Type |
Complaint |
Activity Nr |
1084339 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2016-06-22 |
Abatement Due Date |
2016-06-29 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-07-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not seperated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at least one-half hour. a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, acetylene fuel gas cylinders were stored right next to oxygen cylinders resulting in a fire hazard. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2016-06-22 |
Abatement Due Date |
2016-07-05 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-07-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, employees used bench grinders with tool rests either missing or not safely adjusted with gaps of 1 1/4 inches between the tool rest and the wheel periphery. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2016-06-22 |
Abatement Due Date |
2016-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, employees used a bench grinder with gaps of 2 inches measured between the abrasive wheel and the tongue guard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2016-06-22 |
Abatement Due Date |
2016-07-12 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-07-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, a hydraulic shear was used with part of its finger guard broken off exposing employees to amputation hazards from the hold-downs and the shear blade. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100253 B02 IV |
Issuance Date |
2016-06-22 |
Abatement Due Date |
2016-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, acetylene cylinders were observed in the cylinder storage area (in storage) to be missing valve protection caps. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100178 L |
Issuance Date |
2016-06-22 |
Abatement Due Date |
2016-07-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, forklift operators had not been trained on safe forklift operation. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
2016-06-22 |
Abatement Due Date |
2016-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, portable power strips were used in an industrial environment with equipment such as grinders. This condition of usage violates their UL rating. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100147 D04 I |
Issuance Date |
2016-06-22 |
Abatement Due Date |
2016-06-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, maintenance was performed on a hydraulic shear and the energy isolating device was not locked out. |
|
|