Search icon

HOMEOWNER BUILDING SERVICES INC. - Florida Company Profile

Company Details

Entity Name: HOMEOWNER BUILDING SERVICES INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

HOMEOWNER BUILDING SERVICES INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 01 Jun 2006 (19 years ago)
Last Event: CANCEL ADM DISS/REV
Event Date Filed: 16 Feb 2010 (15 years ago)
Document Number: P06000076212
FEI/EIN Number 562595974

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 739 BROOKMONT AVENUE EAST, JACKSONVILLE, FL, 32211, US
Mail Address: 739 BROOKMONT AVENUE EAST, JACKSONVILLE, FL, 32211, US
ZIP code: 32211
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ALEXANDER GLENN R President 739 BROOKMONT AVENUE EAST, JACKSONVILLE, FL, 32211
Alexander Daniel R Vice President 3255 FRUITWOOD LANE, JACKSONVILLE, FL, 32277
ALEXANDER GLENN R Agent 739 BROOKMONT AVENUE EAST, JACKSONVILLE, FL, 32211

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2023-04-09 739 BROOKMONT AVENUE EAST, JACKSONVILLE, FL 32211 -
CHANGE OF MAILING ADDRESS 2023-04-09 739 BROOKMONT AVENUE EAST, JACKSONVILLE, FL 32211 -
REGISTERED AGENT ADDRESS CHANGED 2023-04-09 739 BROOKMONT AVENUE EAST, JACKSONVILLE, FL 32211 -
CANCEL ADM DISS/REV 2010-02-16 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2009-09-25 - -

Documents

Name Date
ANNUAL REPORT 2024-04-29
ANNUAL REPORT 2023-04-09
ANNUAL REPORT 2022-04-27
ANNUAL REPORT 2021-04-20
ANNUAL REPORT 2020-06-23
ANNUAL REPORT 2019-04-26
ANNUAL REPORT 2018-04-10
ANNUAL REPORT 2017-04-08
ANNUAL REPORT 2016-04-16
ANNUAL REPORT 2015-04-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337432819 0419700 2012-11-15 2047 MATEFIELD RD, JACKSONVILLE, FL, 32225
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-11-15
Emphasis L: FALL, L: EISAOF
Case Closed 2013-02-20

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2012-12-11
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2012-12-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about November 15, 2012, on the 6:12 pitch roof, employees re-roofing the residential house were exposed to an 8 feet fall hazard in that they were not protected by a fall protection system.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2012-12-11
Abatement Due Date 2013-01-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-12-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about November 15, 2012, employees who worked from the 6:12 pitch roof were not trained to recognize fall hazards or the procedures to minimize these hazards.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2012-12-11
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2012-12-18
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about November 15, 2012, at the northwest corner of the house, the ladder used to access the roof did not extend at least 36 inches above the roof eave.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2012-12-11
Abatement Due Date 2013-01-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-12-18
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, that enabled each employee to recognize hazards related to ladders and stairways, and that trained each employee in the procedures to be followed to minimize those hazards: a. On or about November 15, 2012, employees using a ladder to access the roof were not trained to recognize hazards related to ladders or the procedures to minimize those hazards.