Search icon

ARTISAN BUILDERS INC.

Company Details

Entity Name: ARTISAN BUILDERS INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit
Status: Inactive
Date Filed: 04 Apr 2006 (19 years ago)
Date of dissolution: 28 Sep 2018 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 28 Sep 2018 (6 years ago)
Document Number: P06000047843
FEI/EIN Number 204637592
Address: 630 EATON ST, KEY WEST, FL, 33040, US
Mail Address: 642 MOULTON AVE W14, LOS ANGELES, CA, 90031, US
ZIP code: 33040
County: Monroe
Place of Formation: FLORIDA

Agent

Name Role Address
MCGILL JAMES M Agent 630 EATON ST, KEY WEST, FL, 33040

President

Name Role Address
MCGILL JAMES M President 630 EATON ST, KEY WEST, FL, 33040

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2018-09-28 No data No data
CHANGE OF MAILING ADDRESS 2017-05-18 630 EATON ST, KEY WEST, FL 33040 No data
REINSTATEMENT 2014-10-01 No data No data
CHANGE OF PRINCIPAL ADDRESS 2014-10-01 630 EATON ST, KEY WEST, FL 33040 No data
REGISTERED AGENT ADDRESS CHANGED 2014-10-01 630 EATON ST, KEY WEST, FL 33040 No data
ADMIN DISSOLUTION FOR ANNUAL REPORT 2014-09-26 No data No data
AMENDMENT 2006-07-14 No data No data

Documents

Name Date
ANNUAL REPORT 2017-07-01
ANNUAL REPORT 2016-03-03
ANNUAL REPORT 2015-04-23
REINSTATEMENT 2014-10-01
ANNUAL REPORT 2013-04-15
ANNUAL REPORT 2012-01-06
ANNUAL REPORT 2011-01-05
ANNUAL REPORT 2010-01-07
ANNUAL REPORT 2009-03-30
ANNUAL REPORT 2008-02-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338352438 0418800 2013-01-16 1216 WHITE ST., KEY WEST, FL, 33040
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-01-16
Emphasis L: FALL, L: EISAOF, P: FALL
Case Closed 2013-05-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260304 I01
Issuance Date 2013-04-25
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-05-17
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood whcih completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a. On or about January 16, 2013, at the above addressed job site, an employee was exposed to an amputation hazard while operating a table saw that lacked a protective guard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-04-25
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-05-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about January 16, 2013, at the above addressed job site, employees were exposed to fall hazards while working near the edge of a roof without the use of fall protection systems.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2013-04-25
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-05-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a. On or about January 16, 2013, at the above addressed job site, an employee was exposed to a fall hazard while accessing a roof with a an A-frame ladder that was placed against a wall.