Search icon

ALLIED ROOFING SYSTEMS, CO., - Florida Company Profile

Company Details

Entity Name: ALLIED ROOFING SYSTEMS, CO.,
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ALLIED ROOFING SYSTEMS, CO., is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 09 Mar 2006 (19 years ago)
Document Number: P06000034474
FEI/EIN Number 562564203

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7050 N.W. 42 ST., MIAMI, FL, 33166, US
Mail Address: P.O. BOX 669353, MIAMI, FL, 33166, US
ZIP code: 33166
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BRINGUIER JOHANNA Director 7050 NW 42 ST, MIAMI, FL, 33166
ARRICK BRUCE A Agent 9130 SOUTH DADELAND BLVD, MIAMI, FL, 33156

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2010-03-25 ARRICK, BRUCE APA -
REGISTERED AGENT ADDRESS CHANGED 2010-03-25 9130 SOUTH DADELAND BLVD, SUITE 1500, MIAMI, FL 33156 -

Documents

Name Date
ANNUAL REPORT 2024-03-11
ANNUAL REPORT 2023-04-11
ANNUAL REPORT 2022-03-21
ANNUAL REPORT 2021-03-23
ANNUAL REPORT 2020-03-13
ANNUAL REPORT 2019-04-04
ANNUAL REPORT 2018-05-01
ANNUAL REPORT 2017-01-18
ANNUAL REPORT 2016-03-14
ANNUAL REPORT 2015-01-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339356545 0418800 2013-08-22 900 COLLINS AVE., MIAMI BEACH, FL, 33139
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2013-08-22
Emphasis L: FALL
Case Closed 2014-10-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2013-09-24
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-10-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide: On or about August 22, 2013, at the above addressed jobsite, the scaffold platform was 10 inches wide.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2013-09-24
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-10-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about August 22, 2013, at the above addressed jobsite, the scaffold components (ladders) were not inspected by the employer or the employee.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 N02
Issuance Date 2013-09-24
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-10-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(n)(2): All ladders used in conjunction with step, platform and trestle ladder scaffolds did not meet the pertinent requirements of subpart X of this part -- Stairways and Ladders, except that job-made ladders were used to support such scaffolds. On or about August 22, 2013, at the above addressed jobsite, one ladder had broken rungs and the other ladder was a job made ladder.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2013-09-24
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2013-10-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety net: On or about August 22, 2013, at the above addressed jobsite, an employee was working on a flat roof without fall protection.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-09-24
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-10-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about August 22, 2013, at the above addressed jobsite, an employee used a job made ladder to gain access to a roof and it did not extend three feet above the landing.

Date of last update: 02 Apr 2025