Entity Name: | A.J.B. CONSTRUCTION, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
A.J.B. CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 26 Sep 2005 (20 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 14 Oct 2011 (14 years ago) |
Document Number: | P05000132097 |
FEI/EIN Number |
203561909
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 288 DANIELS POINTE DR, WINTER GARDEN, FL, 34787, US |
Mail Address: | 288 DANIELS POINTE DR, WINTER GARDEN, FL, 34787, US |
ZIP code: | 34787 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ADRIANO ALEJANDRO | President | 288 DANIELS POINT DR, WINTER GARDEN, FL, 34787 |
ADRIANO ALEJANDRO | Agent | 288 DANIELS POINT DR, WINTER GARDEN, FL, 34787 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2022-04-12 | 288 DANIELS POINTE DR, WINTER GARDEN, FL 34787 | - |
CHANGE OF MAILING ADDRESS | 2022-04-12 | 288 DANIELS POINTE DR, WINTER GARDEN, FL 34787 | - |
REINSTATEMENT | 2011-10-14 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2011-09-23 | - | - |
CANCEL ADM DISS/REV | 2009-10-19 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2008-09-26 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-06 |
ANNUAL REPORT | 2023-04-29 |
ANNUAL REPORT | 2022-04-12 |
ANNUAL REPORT | 2021-03-11 |
ANNUAL REPORT | 2020-01-10 |
ANNUAL REPORT | 2019-02-11 |
ANNUAL REPORT | 2018-02-09 |
ANNUAL REPORT | 2017-03-14 |
ANNUAL REPORT | 2016-04-06 |
ANNUAL REPORT | 2015-05-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345624902 | 0420600 | 2021-11-08 | 1044 BREEZEWOOD DR., LAKELAND, FL, 33809 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2021-12-06 |
Current Penalty | 2194.5 |
Initial Penalty | 2926.0 |
Final Order | 2021-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) On or about 11/10/2021, at the construction site, access ladders were not provided for employees working off of scaffolding at heights of approximately 13 feet and 8 inches. Rather, employees had to climb the frame of the scaffolding. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2021-12-06 |
Current Penalty | 2194.5 |
Initial Penalty | 2926.0 |
Final Order | 2021-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1):Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. On or about 11/08/2021, at the construction site, employees were working off of scaffolding at heights of approximately 13 feet and 8 inches in areas where there were no guardrails installed, exposing them to fall hazards of approximately 13 feet and 8 inches to the ground below. No fall protection was being used. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State