346642093
|
0419700
|
2023-04-18
|
7584 A1A, SAINT AUGUSTINE, FL, 32084
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-05-11
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-07-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2023-06-05 |
Current Penalty |
10938.0 |
Initial Penalty |
10938.0 |
Final Order |
2023-07-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. 7584 A1A, Saint Augustine, FL; On or about April 18, 2023, employees working on a 4:12 pitch roof performing roofing operations, were not protected from a 20-foot fall hazard by use of a guardrail system, safety net system, or personal fall arrest system. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040041 A02 |
Issuance Date |
2023-06-05 |
Current Penalty |
1328.0 |
Initial Penalty |
1328.0 |
Final Order |
2023-07-03 |
Nr Instances |
1 |
Nr Exposed |
27 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.41(a)(2): The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the specified date: (a) A to Z Custom Homes, Inc.; On or about March 2, 2023, the employer failed to electronically submit information from their OSHA Form 300A, Summary of Work-Related Injuries and Illnesses or equivalent form, for calendar year 2022 on or before March 2, 2023. The establishment employed 25 employees during calendar year 2022 and was classified under NAICS code 238160. |
|
|
343797809
|
0419700
|
2019-02-21
|
150 SOUTHPARK BLVD., SAINT AUGUSTINE, FL, 32084
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-02-21
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-01-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2019-03-26 |
Current Penalty |
1932.0 |
Initial Penalty |
3220.0 |
Final Order |
2019-04-03 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On or about February 21, 2019, on a 5:12 pitch roof, employees performing re-roofing operations, were not protected from a 22 foot fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection. |
|
|
341874576
|
0419700
|
2016-10-28
|
105 SGT TUTTEN DR MANNING BUILDING SUPPLY, SAINT AUGUSTINE, FL, 32086
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-10-28
|
Emphasis |
L: FALL
|
Case Closed |
2018-01-12
|
Related Activity
Type |
Referral |
Activity Nr |
1151018 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B05 |
Issuance Date |
2016-11-29 |
Current Penalty |
3741.0 |
Initial Penalty |
4988.0 |
Final Order |
2016-12-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(5): Employee(s) required to handle or use flammable liquids, gases, or toxic materials were not instructed in the safe handling and use of these materials and made aware of the specific requirements contained in 29 CFR 1926, subparts D. a. On or about October 28, 2016 employees were applying a combustible silicone roof coating blended with a highly flammable reducer and were not trained by the employer on how to safely handle, and use these products, exposing employees to burn hazards. In the alternative 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s). |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260150 C01 I |
Issuance Date |
2016-11-29 |
Current Penalty |
0.0 |
Initial Penalty |
2138.0 |
Final Order |
2016-12-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(i): Travel distance from any point of the protected area to the nearest fire extinguisher exceeded 100 feet. a. On or about October 28, 2016 employer did not ensure an adequate suitable fire extinguisher was near the spraying area where employees were spraying a flammable silicone base roof waterproofing. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260152 E02 |
Issuance Date |
2016-11-29 |
Current Penalty |
3741.0 |
Initial Penalty |
4988.0 |
Final Order |
2016-12-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.152(e)(2): The transfer of flammable liquids from one container to another was done when the containers were not electrically interconnected (bonded). a. On or about October 28, 2016 employees transferring flammable liquids, like reducer from 1 gallon cans, and silicone paint into a 5 gallon plastic bucket were exposed to static charges and flash fires because the 5 gallon plastic bucket they were using was not grounded or effectively bounded to the gasoline operated paint sprayer or grounded to the earth, to prevent discharge of static electricity. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260152 I06 |
Issuance Date |
2016-11-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-12-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.152(i)(6): In locations where flammable vapors could have been present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition: a. On or about October 28, 2016 two employees were using combustible residue and explosive vapors in an area directly adjacent to electrical equipment and heat sources. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2016-11-29 |
Current Penalty |
3741.0 |
Initial Penalty |
4988.0 |
Final Order |
2016-12-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a. On or about October 28, 2016 employees had placed a portable A frame fiberglass ladder to gain access to a roof and did not have the top of the ladder extend at least 3 feet above the point of the roofline. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2016-11-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-12-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. On or about October 28, 2016 employees had placed a fiberglass A Frame ladder against an exterior wall in the folded position to gain access to an upper level. The ladder was not used as designed. |
|
|
339594855
|
0419700
|
2014-02-20
|
88 FOREST GROVE DRIVE, PALM COAST, FL, 32164
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-02-20
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2014-04-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2014-03-17 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-04-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems or a combination of warning line system and safety monitoring system. a. On February 202014, on a 4:12 pitch roof, employees laying down waterproof membrane were not protected from a 8-foot 3-inch fall hazard by use of a fall protection system. |
|
|