Search icon

LEBRON ROOFING INC - Florida Company Profile

Company Details

Entity Name: LEBRON ROOFING INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

LEBRON ROOFING INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 15 Aug 2005 (20 years ago)
Date of dissolution: 05 Apr 2022 (3 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 05 Apr 2022 (3 years ago)
Document Number: P05000112785
FEI/EIN Number 203304141

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2901 NE 70TH ST, OCALA, FL, 34479, US
Mail Address: 2901 NE 70TH ST, OCALA, FL, 34479, US
ZIP code: 34479
County: Marion
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LEBRON MELISSA President 2901 NE 70TH ST, OCALA, FL, 34479
LEBRON JONATAN Vice President 2901 NE 70TH ST, OCALA, FL, 34479
LEBRON MELISSA Agent 2901 NE 70TH ST, OCALA, FL, 34479

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G08205900077 EXPRESS ROOFING AND REPAIRS CO. EXPIRED 2008-07-22 2013-12-31 - 10627 NE 10 PLACE, MIAMI SHORES, FL, 33138

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2022-04-05 - -
AMENDMENT 2015-01-20 - -
AMENDMENT 2014-08-14 - -
NAME CHANGE AMENDMENT 2014-04-14 LEBRON ROOFING INC -
CHANGE OF PRINCIPAL ADDRESS 2007-04-23 2901 NE 70TH ST, OCALA, FL 34479 -
CHANGE OF MAILING ADDRESS 2007-04-23 2901 NE 70TH ST, OCALA, FL 34479 -
REGISTERED AGENT ADDRESS CHANGED 2007-04-23 2901 NE 70TH ST, OCALA, FL 34479 -
AMENDMENT 2005-10-27 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J08900010743 LAPSED 08630CC CTY CRT MARION CTY 2008-05-28 2013-06-19 $8469.87 RH DONNELLEY PUBLISHING & ADVERTISING INC, 5000 COLLEGE BLVD STE 201, OVERLAND PARK, KS 66211
J08900010126 LAPSED 08441SCSPC CTY CRT 6 JUD PINELLAS CTY 2008-05-27 2013-06-09 $5560.58 BRADCO SUPPLY CORPORATION, 6944 N US HWY 41, APOLLO BEACH, FL 33572
J08900004505 LAPSED CA 07-22101 MB PALM BEACH CTY CIR CIVIL 2008-02-05 2013-03-21 $33394.82 AMERICAN BUILDERS AND CONTRACTORS SUPPLY COMPANY, INC., 800 NW 65TH STREET, FORT LAUDERDALE, FL 33309

Documents

Name Date
VOLUNTARY DISSOLUTION 2022-04-05
ANNUAL REPORT 2021-03-01
ANNUAL REPORT 2020-06-30
ANNUAL REPORT 2019-04-08
ANNUAL REPORT 2018-03-15
ANNUAL REPORT 2017-04-03
ANNUAL REPORT 2016-04-26
ANNUAL REPORT 2015-04-28
Amendment 2015-01-20
Amendment 2014-08-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341056489 0420600 2015-11-13 3207 W. BEARSS AVE., TAMPA, FL, 33618
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-11-13
Emphasis L: FALL, P: FALL
Case Closed 2016-02-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2016-01-25
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2016-02-05
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 11/13/2015 on the roof of building #3207, employees were exposed to a 10 ft. fall hazard while removing and installing shingles on a 5/12 pitched roof, in that, fall protection was not used.

Date of last update: 02 Apr 2025

Sources: Florida Department of State