Entity Name: | TRI-STATE ROOFERS, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
TRI-STATE ROOFERS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 12 Jul 2005 (20 years ago) |
Date of dissolution: | 11 Dec 2017 (7 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 11 Dec 2017 (7 years ago) |
Document Number: | P05000097981 |
FEI/EIN Number |
203160202
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 158 MONAHAN DRIVE, FORT WALTON BEACH, FL, 32547 |
Mail Address: | 158 MONAHAN DRIVE, FORT WALTON BEACH, FL, 32547 |
ZIP code: | 32547 |
County: | Okaloosa |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
HOWERTER BECKEY L | President | 158 MONAHAN DRIVE, FORT WALTON BEACH, FL, 32547 |
HOWERTER BECKEY L | Agent | 158 MONAHAN DRIVE, FORT WALTON BEACH, FL, 32547 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2017-12-11 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2017-02-13 |
ANNUAL REPORT | 2016-03-29 |
ANNUAL REPORT | 2015-04-30 |
ANNUAL REPORT | 2014-03-25 |
ANNUAL REPORT | 2013-04-01 |
ANNUAL REPORT | 2012-05-01 |
ANNUAL REPORT | 2011-03-23 |
ANNUAL REPORT | 2010-01-25 |
ANNUAL REPORT | 2010-01-15 |
ANNUAL REPORT | 2009-05-06 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
335814380 | 0419700 | 2012-08-18 | 290 MARY ESTHER BLVD, MARY ESTHER, FL, 32569 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2012-09-25 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-10-25 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted: a. On or about August 18, 2012, employees were working on a 4:12 pitch roof without the use of any fall protection systems, being exposed to a 14-foot 2-inch fall hazard. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2012-09-25 |
Abatement Due Date | 2012-10-17 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-10-25 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training: a. On or about August 18, 2012, the employer did not have fall protection training certification documentation for the superintendent and three employees working on the 4:12 pitch roof without fall protection systems. |
Date of last update: 01 May 2025
Sources: Florida Department of State