346568975
|
0419730
|
2023-03-10
|
9000 SOLAY RD, WINTER GARDEN, FL, 34787
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-10
|
Case Closed |
2023-06-23
|
Related Activity
Type |
Inspection |
Activity Nr |
1656891 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1655989 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1655982 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1655987 |
Safety |
Yes |
|
|
342700606
|
0419700
|
2017-10-11
|
1655 PRUDENTIAL DRIVE, JACKSONVILLE, FL, 32207
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-10-12
|
Emphasis |
L: FALL
|
Case Closed |
2018-09-13
|
Related Activity
Type |
Referral |
Activity Nr |
1273626 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1270061 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1270064 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-01-10 |
Abatement Due Date |
2018-02-06 |
Current Penalty |
5000.0 |
Initial Penalty |
6652.0 |
Final Order |
2018-02-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about October 11, 2017: two employees of Acevedos Construction Corp were observed installing floor joist trusses and were walking on the wall top plate; employees were not protected by guardrail system, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure. Employees were exposed to a 9-feet fall hazard. Stick Framing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1216257, citation number 1, item number 1 and was affirmed as a final order on June 15, 2017, with respect to a workplace located at 8300 Osceola Polk Line Road Davenport, FL 33896. |
|
|
342162575
|
0420600
|
2017-03-08
|
8300 OSCEOLA POLK LINE RD, DAVENPORT, FL, 33896
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-03-09
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-06-20
|
Related Activity
Type |
Inspection |
Activity Nr |
1216266 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1216162 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1216281 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1216219 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1230830 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1216294 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1216178 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2017-05-24 |
Current Penalty |
2281.8 |
Initial Penalty |
3803.0 |
Final Order |
2017-06-15 |
Nr Instances |
4 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Buildings 12, 14, and 15, employees were exposed to a 9 foot fall hazard, in that, access from the ground to the second floor was through an open-sided breezeway landing, on or about 03/08/2017. b. Buildings 12, 14, and 15, employees were exposed to an 18 foot fall hazard, in that, balconies on the second and third floors in all three buildings were open sided, on or about 03/08/2017. c. Buildings 12, 14 and 15, employees were exposed to a 9 foot fall hazard, in that, access from the second floor to the third floor was through floor holes which did not have railings installed, on or about 03/08/2017. d. Buildings 12, 14, and 15, employees were exposed to an 18 foot fall hazard, in that, windows on the second and third floors in all three buildings were not provided with a railing system as required, on or about 03/08/2017. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260502 B13 |
Issuance Date |
2017-05-24 |
Abatement Due Date |
2017-05-31 |
Current Penalty |
1629.6 |
Initial Penalty |
2716.0 |
Final Order |
2017-06-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(13): When guardrail systems were used around holes which were used as access (such as ladderways), they were not provided with a gate, or were not so offset that a person could not walk directly into the hole: a. Buildings 9, 10, 11 and 13, employees were exposed to a 9 foot fall hazard, in that, access from the second floor to the third floor was through floor holes which did not have a gate or railings installed in such a manner as to offset the fall into the floor hole, on or about 03/08/2017. |
|
|
339564965
|
0420600
|
2014-01-28
|
11209 RANCH CREEK TERRACE, BRADENTON, FL, 34211
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-01-29
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2014-02-07
|
Related Activity
Type |
Inspection |
Activity Nr |
956472 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
956528 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
956556 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
956523 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
956513 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
956506 |
Safety |
Yes |
|
|