Search icon

STICK FRAMING, INC.

Company Details

Entity Name: STICK FRAMING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit
Status: Active
Date Filed: 13 Jan 2005 (20 years ago)
Last Event: AMENDMENT
Event Date Filed: 02 Jan 2020 (5 years ago)
Document Number: P05000007648
FEI/EIN Number 562496969
Address: 607 SHORE DRIVE E, OLDSMAR, FL, 34677, US
Mail Address: 607 SHORE DRIVE E, OLDSMAR, FL, 34677, US
ZIP code: 34677
County: Pinellas
Place of Formation: FLORIDA

Agent

Name Role Address
THOMAS JONES SUSAN Agent 607 SHORE DR. E., OLDSMAR, FL, 34677

President

Name Role Address
JONES SUSAN President 607 SHORE DR. E., OLDSMAR, FL, 34677

Events

Event Type Filed Date Value Description
AMENDMENT 2020-01-02 No data No data
REGISTERED AGENT NAME CHANGED 2020-01-02 THOMAS JONES, SUSAN No data
CHANGE OF PRINCIPAL ADDRESS 2018-03-09 607 SHORE DRIVE E, OLDSMAR, FL 34677 No data
CHANGE OF MAILING ADDRESS 2018-03-09 607 SHORE DRIVE E, OLDSMAR, FL 34677 No data
REGISTERED AGENT ADDRESS CHANGED 2018-03-09 607 SHORE DR. E., OLDSMAR, FL 34677 No data

Documents

Name Date
ANNUAL REPORT 2024-02-05
ANNUAL REPORT 2023-03-22
ANNUAL REPORT 2022-04-07
ANNUAL REPORT 2021-04-12
ANNUAL REPORT 2020-03-20
Amendment 2020-01-02
ANNUAL REPORT 2019-04-17
ANNUAL REPORT 2018-03-09
ANNUAL REPORT 2017-02-17
ANNUAL REPORT 2016-01-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346568975 0419730 2023-03-10 9000 SOLAY RD, WINTER GARDEN, FL, 34787
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2023-03-10
Case Closed 2023-06-23

Related Activity

Type Inspection
Activity Nr 1656891
Safety Yes
Type Inspection
Activity Nr 1655989
Safety Yes
Type Inspection
Activity Nr 1655982
Safety Yes
Type Inspection
Activity Nr 1655987
Safety Yes
342700606 0419700 2017-10-11 1655 PRUDENTIAL DRIVE, JACKSONVILLE, FL, 32207
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2017-10-12
Emphasis L: FALL
Case Closed 2018-09-13

Related Activity

Type Referral
Activity Nr 1273626
Safety Yes
Type Inspection
Activity Nr 1270061
Safety Yes
Type Inspection
Activity Nr 1270064
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2018-01-10
Abatement Due Date 2018-02-06
Current Penalty 5000.0
Initial Penalty 6652.0
Final Order 2018-02-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about October 11, 2017: two employees of Acevedos Construction Corp were observed installing floor joist trusses and were walking on the wall top plate; employees were not protected by guardrail system, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure. Employees were exposed to a 9-feet fall hazard. Stick Framing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1216257, citation number 1, item number 1 and was affirmed as a final order on June 15, 2017, with respect to a workplace located at 8300 Osceola Polk Line Road Davenport, FL 33896.
342162575 0420600 2017-03-08 8300 OSCEOLA POLK LINE RD, DAVENPORT, FL, 33896
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2017-03-09
Emphasis L: FALL, P: FALL
Case Closed 2017-06-20

Related Activity

Type Inspection
Activity Nr 1216266
Safety Yes
Type Inspection
Activity Nr 1216162
Safety Yes
Type Inspection
Activity Nr 1216281
Safety Yes
Type Inspection
Activity Nr 1216219
Safety Yes
Type Inspection
Activity Nr 1230830
Safety Yes
Type Inspection
Activity Nr 1216294
Safety Yes
Type Inspection
Activity Nr 1216178
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-05-24
Current Penalty 2281.8
Initial Penalty 3803.0
Final Order 2017-06-15
Nr Instances 4
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Buildings 12, 14, and 15, employees were exposed to a 9 foot fall hazard, in that, access from the ground to the second floor was through an open-sided breezeway landing, on or about 03/08/2017. b. Buildings 12, 14, and 15, employees were exposed to an 18 foot fall hazard, in that, balconies on the second and third floors in all three buildings were open sided, on or about 03/08/2017. c. Buildings 12, 14 and 15, employees were exposed to a 9 foot fall hazard, in that, access from the second floor to the third floor was through floor holes which did not have railings installed, on or about 03/08/2017. d. Buildings 12, 14, and 15, employees were exposed to an 18 foot fall hazard, in that, windows on the second and third floors in all three buildings were not provided with a railing system as required, on or about 03/08/2017.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260502 B13
Issuance Date 2017-05-24
Abatement Due Date 2017-05-31
Current Penalty 1629.6
Initial Penalty 2716.0
Final Order 2017-06-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(13): When guardrail systems were used around holes which were used as access (such as ladderways), they were not provided with a gate, or were not so offset that a person could not walk directly into the hole: a. Buildings 9, 10, 11 and 13, employees were exposed to a 9 foot fall hazard, in that, access from the second floor to the third floor was through floor holes which did not have a gate or railings installed in such a manner as to offset the fall into the floor hole, on or about 03/08/2017.
339564965 0420600 2014-01-28 11209 RANCH CREEK TERRACE, BRADENTON, FL, 34211
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2014-01-29
Emphasis N: CTARGET, P: CTARGET
Case Closed 2014-02-07

Related Activity

Type Inspection
Activity Nr 956472
Safety Yes
Type Inspection
Activity Nr 956528
Safety Yes
Type Inspection
Activity Nr 956556
Safety Yes
Type Inspection
Activity Nr 956523
Health Yes
Type Inspection
Activity Nr 956513
Safety Yes
Type Inspection
Activity Nr 956506
Safety Yes

Date of last update: 03 Feb 2025

Sources: Florida Department of State