Entity Name: | D H FRAMING & CONSTRUCTION, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
D H FRAMING & CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 30 Jul 2004 (21 years ago) |
Document Number: | P04000112390 |
FEI/EIN Number |
593066653
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 8513 RICHMOND STREET, GIBSONTON, FL, 33534 |
Mail Address: | 8513 RICHMOND STREET, GIBSONTON, FL, 33534 |
ZIP code: | 33534 |
County: | Hillsborough |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
HARTER DANNY C | President | 8513 RICHMOND STREET, GIBSONTON, FL, 33534 |
HARTER DANNY C | Secretary | 8513 RICHMOND STREET, GIBSONTON, FL, 33534 |
HARTER DANNY C | Treasurer | 8513 RICHMOND STREET, GIBSONTON, FL, 33534 |
HARTER DANNY C | Agent | 8513 RICHMOND STREET, GIBSONTON, FL, 33534 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G13000018261 | D H FRAMING & MARINE | EXPIRED | 2013-02-21 | 2018-12-31 | - | 8513 RICHMOND STREET, GIBSONTON, FL, 33534 |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-25 |
ANNUAL REPORT | 2023-04-25 |
ANNUAL REPORT | 2022-04-28 |
ANNUAL REPORT | 2021-04-19 |
ANNUAL REPORT | 2020-06-10 |
ANNUAL REPORT | 2019-04-26 |
ANNUAL REPORT | 2018-04-25 |
ANNUAL REPORT | 2017-04-27 |
ANNUAL REPORT | 2016-04-21 |
ANNUAL REPORT | 2015-04-09 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342588621 | 0420600 | 2017-08-25 | 8730 W LINEBAUGH AVE, TAMPA, FL, 33625 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2017-10-02 |
Current Penalty | 1630.0 |
Initial Penalty | 1630.0 |
Final Order | 2017-10-31 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. At the site, employees were exposed to an overhead hazard when protection such as a hard hat was not used while standing directly below truss installation work, on or about 08/25/2017. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B15 |
Issuance Date | 2017-10-02 |
Current Penalty | 3259.0 |
Initial Penalty | 3259.0 |
Final Order | 2017-10-31 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system: a. At the site, an employee was exposed to a 12 foot fall hazard, in that, during truss installation the employee was standing on the truss being installed and on a 2x4 nailed on the framing below the truss, on or about 08/25/2017. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2017-10-02 |
Current Penalty | 2173.0 |
Initial Penalty | 2173.0 |
Final Order | 2017-10-31 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. At the site, an employee was exposed to a 10 foot fall hazard, in that, a 10 foot aluminum step ladder was used by stepping on the top of the ladder to gain access to the trusses, on or about 08/25/2017. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2011-11-21 |
Case Closed | 2012-03-28 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2011-12-01 |
Abatement Due Date | 2011-12-06 |
Initial Penalty | 1800.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 01 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19261060 A |
Issuance Date | 2011-12-01 |
Abatement Due Date | 2011-12-13 |
Nr Instances | 1 |
Nr Exposed | 1 |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2006-09-11 |
Emphasis | L: FALL |
Case Closed | 2007-07-23 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 C02 IV |
Issuance Date | 2006-09-18 |
Abatement Due Date | 2006-09-21 |
Current Penalty | 1500.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2006-09-18 |
Abatement Due Date | 2006-09-21 |
Current Penalty | 1500.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2005-08-18 |
Emphasis | L: FALL |
Case Closed | 2005-10-11 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2005-09-02 |
Abatement Due Date | 2005-09-08 |
Current Penalty | 100.0 |
Initial Penalty | 700.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 02 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19261060 A |
Issuance Date | 2005-09-02 |
Abatement Due Date | 2005-09-15 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 01 |
Date of last update: 01 Mar 2025