Entity Name: | A-TEAM GENERAL CONTRACTORS GROUP, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
A-TEAM GENERAL CONTRACTORS GROUP, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 01 Apr 2004 (21 years ago) |
Date of dissolution: | 10 Mar 2020 (5 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 10 Mar 2020 (5 years ago) |
Document Number: | P04000056592 |
FEI/EIN Number |
432068203
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2805 sw 144 pl, MIAMI, FL, 33175, US |
Mail Address: | 2805 sw 144 pl, MIAMI, FL, 33175, US |
ZIP code: | 33175 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SANTANA YOURDETTY P | President | 2805 sw 144 pl, MIAMI, FL, 33175 |
SANTANA YOURDETTY P | Director | 2805 sw 144 pl, MIAMI, FL, 33175 |
LEYVA ALEXEY V | Vice President | 2805 sw 144 pl, MIAMI, FL, 33175 |
SANTANA YOURDETTY | Agent | 2805 sw 144 pl, MIAMI, FL, 33175 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2020-03-10 | - | - |
REGISTERED AGENT NAME CHANGED | 2016-04-19 | SANTANA, YOURDETTY | - |
AMENDMENT | 2013-07-18 | - | - |
AMENDMENT | 2013-07-05 | - | - |
REGISTERED AGENT ADDRESS CHANGED | 2013-04-01 | 2805 sw 144 pl, MIAMI, FL 33175 | - |
CHANGE OF PRINCIPAL ADDRESS | 2013-04-01 | 2805 sw 144 pl, MIAMI, FL 33175 | - |
CHANGE OF MAILING ADDRESS | 2013-04-01 | 2805 sw 144 pl, MIAMI, FL 33175 | - |
NAME CHANGE AMENDMENT | 2007-12-10 | A-TEAM GENERAL CONTRACTORS GROUP, INC. | - |
AMENDMENT | 2006-11-29 | - | - |
AMENDMENT | 2006-09-14 | - | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J18000418251 | LAPSED | 17-099-D5 | LEON | 2018-05-15 | 2023-06-21 | $198,542.98 | DFS DIVISION OF WORKERS COMPENSATION, 200 EAST GAINES STREET, TALLAHASSEE, FL 32399-4228 |
J13001379453 | TERMINATED | 1000000470549 | MIAMI-DADE | 2013-09-03 | 2033-09-12 | $ 330.00 | STATE OF FLORIDA, DEPARTMENT OF REVENUE, MIAMI SERVICE CENTER, 8175 NW 12TH ST STE 119, DORAL FL331261828 |
Name | Date |
---|---|
VOLUNTARY DISSOLUTION | 2020-03-10 |
ANNUAL REPORT | 2019-04-08 |
ANNUAL REPORT | 2018-03-18 |
ANNUAL REPORT | 2017-02-23 |
ANNUAL REPORT | 2016-04-19 |
ANNUAL REPORT | 2015-04-07 |
ANNUAL REPORT | 2014-03-21 |
Amendment | 2013-07-18 |
Amendment | 2013-07-05 |
ANNUAL REPORT | 2013-04-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341721678 | 0418800 | 2016-08-24 | 16521 SW 1ST STREET, MIRAMAR, FL, 33027 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1128811 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2016-09-30 |
Current Penalty | 3741.0 |
Initial Penalty | 3741.0 |
Final Order | 2016-11-02 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system: On or about 08/24/2016, at the above addressed work site, employees working on a roof without fall protection were exposed to a fall hazard of at least 10-feet. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19101200 E01 |
Issuance Date | 2016-09-30 |
Abatement Due Date | 2016-10-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2016-11-02 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Referral |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about 08/24/2016, at the above addressed work site, the employer did not develop or implement a written hazard communication Program for employees exposed to hazardous chemicals, such as but not limited to Tarnak (roof tar) and cement. |
Citation ID | 03001 |
Citaton Type | Other |
Standard Cited | 19030019 C01 |
Issuance Date | 2017-02-21 |
Abatement Due Date | 2017-02-27 |
Current Penalty | 305.0 |
Initial Penalty | 305.0 |
Final Order | 2017-03-23 |
Nr Instances | 1 |
Nr Exposed | 8 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: On or about 10/13/2016, the employer did not send abatement documentation for citation 2 item 1 contained in Inspection #1172167, which was issued on 09/30/2016. |
Inspection Type | Complaint |
Scope | NoInspection |
Safety/Health | Safety |
Close Conference | 2016-04-22 |
Case Closed | 2016-04-28 |
Related Activity
Type | Complaint |
Activity Nr | 1081753 |
Safety | Yes |
Date of last update: 01 May 2025