Entity Name: | SMITH ROOFING OF CLERMONT, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
SMITH ROOFING OF CLERMONT, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 31 Dec 2003 (21 years ago) |
Date of dissolution: | 01 Oct 2004 (21 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 01 Oct 2004 (21 years ago) |
Document Number: | P04000006194 |
Address: | P.O. BOX 121072, CLERMONT, FL, 34712 |
Mail Address: | P.O. BOX 121072, CLERMONT, FL, 34712 |
ZIP code: | 34712 |
County: | Lake |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SMITH SUSAN M | President | P.O. BOX 121072, CLERMONT, FL, 34712 |
SMITH SUSAN M | Agent | 284 W. MINNEOLA AVE., CLERMONT, FL, 34711 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2004-10-01 | - | - |
Name | Date |
---|---|
Domestic Profit | 2003-12-31 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338998594 | 0420600 | 2013-04-10 | 8000 CHERRY RD, GROVELAND, FL, 34736 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 812728 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-05-03 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-06-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) front of house - roof - employees were exposed to a fall of 12 feet 7 inches while installing metal shingles. The slope of the roof was 4/12 and 6/12, on or about 4/10/13. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-05-03 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-06-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Front of house - the employees were exposed to a fall of 10 feet 10 inches, in that, they were using a folding ladder that extended only a couple of inches above the landing, on or about 4/10/13. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B09 |
Issuance Date | 2013-05-03 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-06-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear: (a) front of house - roof - the employees were exposed to a fall of 10 feet 10 inches, in that, metal roofing shingles and a wood slide guard were stored directly at the top of the ladder landing area, on or about 4/10/13. |