340782465
|
0419700
|
2015-07-14
|
11211 ATLANTIC BLVD. FIELDS JAGUAR CARWASH AREA, JACKSONVILLE, FL, 32216
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-07-14
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2015-09-08
|
Related Activity
Type |
Inspection |
Activity Nr |
1078277 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B12 |
Issuance Date |
2015-08-13 |
Current Penalty |
3920.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-09-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(12): "Precast concrete erection." Each employee engaged in the erection of precast concrete members (including, but not limited to the erection of wall panels, columns, beams, and floor and roof "tees") and related operations such as grouting of precast concrete members, who is 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, or personal fall arrest systems, unless another provision in paragraph (b) of this section provides for an alternative fall protection measure: a. On or about July 14,2015, Fields Jaguar Carwash roof area, two employees laying out concrete slabs were not protected from falling 13 feet 10-inches to the ground by the use of a guardrail system, safety net system, personal fall arrest system or any other type of fall protection method. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260701 B |
Issuance Date |
2015-08-13 |
Current Penalty |
1280.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-09-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement: a. On or about July 14, 2015, Fields Jaguar Carwash roof area, the 2-foot rebar protruding out of the wall was not guarded to prevent impalement to employees working. |
|
|
339497984
|
0418800
|
2013-11-20
|
FEDERAL HIGHWAY AND NE 6TH ST., FORT LAUDERDALE, FL, 33304
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-04-10
|
Emphasis |
L: FALL
|
Case Closed |
2014-10-16
|
Related Activity
Type |
Complaint |
Activity Nr |
862292 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260704 A |
Issuance Date |
2014-04-28 |
Abatement Due Date |
2014-05-08 |
Current Penalty |
7546.0 |
Initial Penalty |
10780.0 |
Final Order |
2014-05-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.704(a): Precast concrete wall units, structural framing and tilt-up wall panels were not adequately supported to prevent overturning and to prevent collapse until permanent connections were completed: On or about November 13, 2013, two walls (W-13 and W-14) collapsed on the west side of the parking garage because they were not properly supported to prevent them from overturning. The Solar Erectors U.S. Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.704(a), which was contained in OSHA inspection number 706018, citation number 1, item number 2 and was affirmed as a final order on April 30, 2013, with respect to a workplace located at 3800 NW 115th Avenue, Doral, FL 33178. |
|
|
337060180
|
0418800
|
2012-10-12
|
3800 NW 115TH AVE., DORAL, FL, 33178
|
|
Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-10-12
|
Case Closed |
2013-05-06
|
Related Activity
Type |
Accident |
Activity Nr |
636250 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2013-04-08 |
Abatement Due Date |
2013-04-25 |
Current Penalty |
6930.0 |
Initial Penalty |
6930.0 |
Final Order |
2013-04-30 |
Nr Instances |
1 |
Nr Exposed |
120 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees when they were exposed to struck-by and caught-in-between hazards: On or about 10/10/12, at the above addressed jobsite, employees were exposed to the risk of being struck by collapsing pre-cast structural members due to not ensuring that column B-3 was properly grouted. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow and implement the Coreslab Erection Drawing E0.0 General Notes, Section 3.2 Welding, which requires welding of connections shall follow closely behind the erection of units. Also, ensure Section 3.4 Grout and Solar Erectors erection procedure in the column section, item #4 are followed. NOTE: ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED FOR THIS ITEM. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260704 A |
Issuance Date |
2013-04-08 |
Abatement Due Date |
2013-04-25 |
Current Penalty |
6930.0 |
Initial Penalty |
6930.0 |
Final Order |
2013-04-30 |
Nr Instances |
1 |
Nr Exposed |
120 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.704(a): Precast concrete wall units, structural framing and tilt-up wall panels were not adequately supported to prevent overturning and to prevent collapse until permanent connections were completed: On or about 10/10/12, at the above addressed jobsite, employees were exposed to the risk of being struck-by collapsing pre-cast structural members due to column B-2 not being braced. NOTE: ABETEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED FOR THIS ITEM. |
|
|
316248244
|
0420600
|
2011-12-09
|
5001 LAKEWOOD RANCH BLVD N, BRADENTON, FL, 34211
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-12-13
|
Emphasis |
S: CONSTRUCTION, S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR
|
Case Closed |
2012-02-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260502 D16 III |
Issuance Date |
2012-01-20 |
Abatement Due Date |
2012-01-25 |
Current Penalty |
1750.0 |
Initial Penalty |
3500.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
05 |
|
|
312151962
|
0418800
|
2008-12-10
|
10501 NW 121 WAY, MEDLEY, FL, 33178
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Emphasis |
N: SSTARG08
|
Case Closed |
2008-12-15
|
|
311090328
|
0418800
|
2008-03-17
|
10501 NW 121 WAY, MEDLEY, FL, 33178
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-03-24
|
Case Closed |
2008-04-29
|
Related Activity
Type |
Referral |
Activity Nr |
200689073 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2008-04-01 |
Abatement Due Date |
2008-04-07 |
Current Penalty |
1250.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
Hazard |
CRUSHING |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 |
Issuance Date |
2008-04-01 |
Abatement Due Date |
2008-04-07 |
Current Penalty |
1250.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
|
|
310449699
|
0420600
|
2006-10-30
|
9500 VIA ENCINAS, ORLANDO, FL, 32830
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2006-10-31
|
Emphasis |
S: ELECTRICAL
|
Case Closed |
2007-10-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2007-01-23 |
Abatement Due Date |
2007-01-29 |
Current Penalty |
625.0 |
Initial Penalty |
1250.0 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260351 B03 |
Issuance Date |
2007-01-23 |
Abatement Due Date |
2007-01-29 |
Current Penalty |
625.0 |
Initial Penalty |
1250.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260351 D01 |
Issuance Date |
2007-01-23 |
Abatement Due Date |
2007-01-26 |
Current Penalty |
625.0 |
Initial Penalty |
1250.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260351 D03 |
Issuance Date |
2007-01-23 |
Abatement Due Date |
2007-01-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2007-01-23 |
Abatement Due Date |
2007-01-26 |
Current Penalty |
875.0 |
Initial Penalty |
1750.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 II |
Issuance Date |
2007-01-23 |
Abatement Due Date |
2007-01-26 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 III |
Issuance Date |
2007-01-23 |
Abatement Due Date |
2007-01-26 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|