347564767
|
0419700
|
2024-06-20
|
8475 WESTERN WAY STE 210, JACKSONVILLE, FL, 32256
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-06-20
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2024-10-29
|
Related Activity
Type |
Referral |
Activity Nr |
2173443 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2024-09-05 |
Current Penalty |
8000.0 |
Initial Penalty |
16131.0 |
Final Order |
2024-09-20 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a. At Piedmont National Corporation, located at 8475 Western Way Ste 210, in Jacksonville, FL: On or about June 12, 2024, employee(s) engaged in material handling operations were exposed to struck-by/crushing hazards in the event of a forklift tip-over and ejection from the operator's seat where safety belts were not worn. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 II A |
Issuance Date |
2024-09-05 |
Current Penalty |
8000.0 |
Initial Penalty |
13828.0 |
Final Order |
2024-09-20 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(ii)(A): Refresher training in relevant topics was not provided to operator(s) when the operator was observed operating the vehicle in an unsafe manner: a. At Piedmont National Corporation, located at 8475 Western Way Ste 210, in Jacksonville, FL: On or about June 12, 2024, the employer exposed employees to struck by and crushed by hazards, in the employer did not retrain an operator after been observed operating the vehicle in an unsafe manner, such as but not limited to excessive speed and not wearing seat belts. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 L04 III |
Issuance Date |
2024-09-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a. At Piedmont National Corporation, located at 8475 Western Way Ste 210, in Jacksonville, FL: On or about June 20, 2024, the employer did not ensure that an evaluation of each powered industrial truck operator's performance was being conducted at least once every three years, in that one forklift operator had not been evaluated since October 26, 2023. |
|
|
339277139
|
0420600
|
2013-08-08
|
5501-A AIRPORT BLVD., TAMPA, FL, 33634
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-08-08
|
Case Closed |
2013-08-14
|
Related Activity
Type |
Inspection |
Activity Nr |
903780 |
Safety |
Yes |
|
|
339037764
|
0420600
|
2013-05-01
|
5501-A AIRPORT BLVD., TAMPA, FL, 33634
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-05-01
|
Emphasis |
L: FORKLIFT
|
|
339037806
|
0420600
|
2013-05-01
|
5501-A AIRPORT BLVD., TAMPA, FL, 33634
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-05-01
|
Emphasis |
L: EISAOF, L: EISAX, L: FORKLIFT
|
Case Closed |
2013-08-14
|
Related Activity
Type |
Complaint |
Activity Nr |
814910 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100157 C01 |
Issuance Date |
2013-05-15 |
Abatement Due Date |
2013-05-21 |
Current Penalty |
1800.0 |
Initial Penalty |
3000.0 |
Final Order |
2013-06-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Main Warehouse -I Section - Zone #1 An ABC portable fire extinguisher was blocked by pallets and not made accessible, on or about, 05/01/13. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100157 G01 |
Issuance Date |
2013-05-15 |
Abatement Due Date |
2013-07-02 |
Current Penalty |
1800.0 |
Initial Penalty |
3000.0 |
Final Order |
2013-06-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(g)(1): Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting. a) Throughout Warehouse Employees were not trained in the use of portable fire extinguishers and the hazards involved with incipient stage firefighting, on or about, 05/01/13. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100176 B |
Issuance Date |
2013-05-15 |
Abatement Due Date |
2013-05-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-04 |
Nr Instances |
2 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) Front Warehouse - WA Area & Rear Warehouse - C Wall Pallets containing empty cardboard boxes and styrofoam boxes were not stacked to prevent sliding and falling onto the warehouse floor, on or about, 05/01/13. |
|
|