Search icon

A-1 STUCCO, INC. - Florida Company Profile

Company Details

Entity Name: A-1 STUCCO, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

A-1 STUCCO, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 19 Dec 2003 (21 years ago)
Date of dissolution: 01 Oct 2004 (21 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 01 Oct 2004 (21 years ago)
Document Number: P03000154887
Address: 10205 OLD SPANISH TRAIL, POLK CITY, FL, 33868, US
Mail Address: 10205 OLD SPANISH TRAIL, POLK CITY, FL, 33868, US
ZIP code: 33868
County: Polk
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
POPE LONNIE F President 10205 OLD SPANISH TRAIL, POLK CITY, FL, 33868
POPE LONNIE F Secretary 10205 OLD SPANISH TRAIL, POLK CITY, FL, 33868
POPE LONNIE F Agent 10205 OLD SPANISH TRAIL, POLK CITY, FL, 33868

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2004-10-01 - -

Documents

Name Date
Domestic Profit 2003-12-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
335170981 0419700 2012-07-10 2297 KINGSLEY AVE., ORANGE PARK, FL, 32065
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2012-07-10
Emphasis L: FALL
Case Closed 2014-11-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2012-09-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2012-10-17
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Variance
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: a. On or about July 10, 2012, the tubular framed scaffold system was missing planks on the second level where employees were installing stucco, exposing employees to a 15 feet fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-09-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2012-10-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a. On or about July 10, 2012, the tubular framed scaffold system, did not have a ladder, exposing employees to a 15 feet fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-09-20
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-10-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about July 10, 2012, the tubular framed scaffold system did not have guardrails on the second level where employees were installing stucco, exposing employees to a 15 feet fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2012-09-20
Abatement Due Date 2012-11-02
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-10-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedures to control or minimize those hazards: a. On or about July 10, 2012, the employer did not train employees about working from scaffold systems and the hazards associated with them.