Entity Name: | SUPREME STUCCO & PLASTERING, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
SUPREME STUCCO & PLASTERING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 12 Dec 2003 (21 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 20 Sep 2012 (13 years ago) |
Document Number: | P03000154830 |
FEI/EIN Number |
200515972
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1095 Tulip Street, ATLANTIC BEACH, FL, 32233, US |
Mail Address: | 1095 Tulip Street, ATLANTIC BEACH, FL, 32233, US |
ZIP code: | 32233 |
County: | Duval |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
DIMITROFF CHETRI L | President | 1095 Tulip Street, ATLANTIC BEACH, FL, 32233 |
Dimitroff Andrea L | Chief Operating Officer | 1095 Tulip Street, Atlantic Beach, FL, 32233 |
DIMITROFF CHETRI L | Agent | 1095 Tulip Street, ATLANTIC BEACH, FL, 32233 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2019-04-30 | 1095 Tulip Street, ATLANTIC BEACH, FL 32233 | - |
CHANGE OF MAILING ADDRESS | 2019-04-30 | 1095 Tulip Street, ATLANTIC BEACH, FL 32233 | - |
REGISTERED AGENT ADDRESS CHANGED | 2019-04-30 | 1095 Tulip Street, ATLANTIC BEACH, FL 32233 | - |
AMENDMENT | 2012-09-20 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-03-03 |
ANNUAL REPORT | 2023-03-13 |
ANNUAL REPORT | 2022-01-28 |
ANNUAL REPORT | 2021-03-15 |
ANNUAL REPORT | 2020-01-09 |
ANNUAL REPORT | 2019-04-30 |
ANNUAL REPORT | 2018-03-15 |
AMENDED ANNUAL REPORT | 2017-06-08 |
ANNUAL REPORT | 2017-03-13 |
ANNUAL REPORT | 2016-02-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345912745 | 0419700 | 2022-04-20 | 50 SILVERFOREST DRIVE 70 SILVERFOREST DRIVE, SAINT AUGUSTINE, FL, 32092 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1591308 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1591268 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1591286 |
Safety | Yes |
Inspection Type | Referral |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-11-02 |
Emphasis | L: FALL |
Case Closed | 2018-09-13 |
Related Activity
Type | Referral |
Activity Nr | 1280547 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1274720 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1274671 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2017-12-05 |
Current Penalty | 3803.0 |
Initial Penalty | 3803.0 |
Final Order | 2018-01-02 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a. On or about November 1, 2017, at the building's front exterior elevation, the employer provided a two-tier scaffold system with access points greater than 2 foot to the scaffold platform, but did not provide a ladder for safe access, thereby exposing a subcontracted employee to caught in and fall hazards when climbing other scaffold components for access to the work platforms. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260451 F03 |
Issuance Date | 2017-12-05 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-01-02 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. On or about November 1, 2017, at the building's front exterior elevation, the employer provided a two-tier scaffold system which was not properly inspected to ensure that a ladder was provided for safe access and that fall protection systems (guard rails) were installed, thereby exposing a subcontracted employee to caught in and fall hazards when working from a scaffold platform. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2017-12-05 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-01-02 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about November 1, 2017, at the building's front exterior elevation, the employer provided a two-tier scaffold system which was not completely erected to prevent fall hazards, thereby exposing a subcontracted employee to fall hazards greater than 14-foot when working from the scaffolds second tier work platforms. |
Date of last update: 01 May 2025
Sources: Florida Department of State