Search icon

BLISS DRYWALL SPECIALTIES INC. - Florida Company Profile

Company Details

Entity Name: BLISS DRYWALL SPECIALTIES INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

BLISS DRYWALL SPECIALTIES INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 20 Nov 2003 (21 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P03000141591
FEI/EIN Number 450529727

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3917 SW Alice St., Port Saint Lucie, FL, 34953, US
Mail Address: 3917 SW Alice St., Port Saint Lucie, FL, 34953, US
ZIP code: 34953
County: St. Lucie
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BLISS SEAN President 3917 SW ALICE ST., PORT ST. LUCIE, FL, 34953
Lemus Jose Officer 19 Hawthorne Ln, Boynton Beach, FL, 33426
ALL FLORIDA FIRM, INC. Agent -

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2018-01-29 3917 SW Alice St., Port Saint Lucie, FL 34953 -
CHANGE OF MAILING ADDRESS 2018-01-29 3917 SW Alice St., Port Saint Lucie, FL 34953 -
REGISTERED AGENT NAME CHANGED 2008-01-03 ALL FLORIDA FIRM, INC. -
REGISTERED AGENT ADDRESS CHANGED 2008-01-03 813 DELTONA BLVD, SUITE A, DELTONA, FL 32725 -

Documents

Name Date
AMENDED ANNUAL REPORT 2018-06-25
ANNUAL REPORT 2018-01-29
ANNUAL REPORT 2017-01-05
ANNUAL REPORT 2016-02-03
ANNUAL REPORT 2015-03-16
ANNUAL REPORT 2014-01-13
ANNUAL REPORT 2013-01-30
ANNUAL REPORT 2012-01-13
ANNUAL REPORT 2011-06-24
ANNUAL REPORT 2010-01-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338319619 0418800 2013-01-17 10333 PINES BLVD, PEMBROKE PINES, FL, 33025
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-01-17
Emphasis P: FALL, L: FALL, L: EISAOF
Case Closed 2014-10-08

Related Activity

Type Inspection
Activity Nr 834226
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2013-05-02
Abatement Due Date 2013-05-02
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2013-06-04
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about January 17, 2013, at the above addressed jobsite, the employer did not ensure that employees, who were using a drill and a circular saw when installing plywood, wore eye or face protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-05-02
Abatement Due Date 2013-05-02
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-06-04
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about January 17, 2013, at the above addressed jobsite, the employer did not ensure that a scaffold being used by employees who were working 14 feet above lower level was fully planked or decked.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2013-05-02
Abatement Due Date 2013-05-02
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-06-04
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about January 17, 2013, at the above addressed jobsite, the employer did not ensure the legs of a tubular scaffold used by the employees had mud sills or base plates.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-05-02
Abatement Due Date 2013-05-14
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2013-06-04
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On or about January 17, 2013, at the above addressed jobsite, the employer did not ensure that employees had an appropriate means of access or egress to the scaffold. Employees utilized the cross braces to climb to the upper level of the scaffold.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2013-05-02
Abatement Due Date 2013-05-02
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-06-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about January 17, 2013, at the above addressed jobsite, employees were exposed to a 14-foot fall hazard while working from a scaffold without the use of a conventional fall protection system.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-05-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-06-04
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about January 17, 2013, at the above addressed jobsite, a scaffold that was being used by employees was not erected under the supervision of a competent person.
Citation ID 01005C
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2013-05-02
Abatement Due Date 2013-05-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-06-04
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. On or about January 17, 2013, at the above addressed jobsite, the employer did not ensure that employees erecting a scaffold were trained.

Date of last update: 01 Apr 2025

Sources: Florida Department of State