336211792
|
0418800
|
2012-09-10
|
10318 NW 55TH STREET, SUNRISE, FL, 33351
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-10-02
|
Emphasis |
L: EISAOF
|
Case Closed |
2013-01-22
|
Related Activity
Type |
Referral |
Activity Nr |
533390 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
604921 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2012-10-26 |
Abatement Due Date |
2012-11-19 |
Current Penalty |
680.0 |
Initial Penalty |
1360.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: On or about 10/2/12, at the M&S Custom Design and Services, Corp. facility, the employer did not perform monitoring when employees were found to be at 86.6dBa time-weighted average during a sampling time of 405 minutes.Zero exposure was assumed for the unsampled period of time (75 minutes). |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2012-10-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about 09/10/12, at the M&S Custom Design and Services, Corp. facility, the employer did not provide Appendix D of the standard to employees wearing a respirator on a voluntary basis. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2012-10-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: On or about 09/10/12, at the M&S Custom Design and Services, Corp. facility, the employer did not provide a medical evaluation and fit testing on employees wearing a respirator as required by the standard. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2012-10-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-26 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: On or about 09/10/12, at M&S Custom Design and Services Corp. facility, the employer did not have a written hazard communication program while employees used chemicals such as an adhesive and paint at the workplace. |
|
|
336049218
|
0418800
|
2012-08-30
|
10318 NW 55TH STREET, SUNRISE, FL, 33351
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-30
|
Emphasis |
L: EISAOF, N: AMPUTATE
|
Case Closed |
2013-11-08
|
Related Activity
Type |
Inspection |
Activity Nr |
621179 |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
529575 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100213 D01 |
Issuance Date |
2012-10-30 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Final Order |
2012-11-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A table saw being used by an employee performing wood working operations did not have a hood to completely enclose the portion of the blade above the table and above the material being cut, on or about August 30, 2012. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100242 A |
Issuance Date |
2012-10-30 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-11-24 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: a) In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A Router was not kept in a safe condition and had the power cord damaged or severed and repaired then covered with masking tape, on or about August 30, 2012. b) In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A Miter Saw was not kept in a safe condition and had the power cord damaged and repaired then covered with masking tape, on or about August 30, 2012. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 |
Issuance Date |
2012-10-30 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2012-11-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: The cover on the electrical box on an air compressor was not in place having the energized wiring and components exposed creating a potential electrocution hazard for employees, on or about August 30, 2012. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2012-10-30 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-11-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: An electrical flexible extension cord powering tools was used as a substitute for fixed wiring of a structure, on or about August 30, 2012. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 II |
Issuance Date |
2012-10-30 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-11-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: An electrical flexible extension cord powering tools was not used in a continuous length where the outer sheath and insulation were compromised and covered with masking tape, on or about August 30, 2012. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2012-10-30 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-11-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A flexible cord supplying power to an air compressor was not connected to the fitting on the electrical box to provide it with strain relief, on or about August 30, 2012. |
|
|