Search icon

WALTER HART MASONRY, INC. - Florida Company Profile

Company Details

Entity Name: WALTER HART MASONRY, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

WALTER HART MASONRY, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 31 Oct 2003 (21 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 24 Oct 2011 (13 years ago)
Document Number: P03000123260
FEI/EIN Number 200357553

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3024 NW 8TH CT., FT. LAUDERDALE, FL, 33311
Mail Address: 3024 NW 8TH CT., FT. LAUDERDALE, FL, 33311
ZIP code: 33311
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
HART WALTER President 3024 NW 8TH CT., FT. LAUDERDALE, FL, 33311
HART WALTER Agent 3024 NW 8TH CT., FT. LAUDERDALE, FL, 33311

Events

Event Type Filed Date Value Description
REINSTATEMENT 2011-10-24 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2011-09-23 - -
AMENDMENT 2003-11-07 - -

Documents

Name Date
ANNUAL REPORT 2024-02-05
ANNUAL REPORT 2023-03-02
ANNUAL REPORT 2022-02-14
ANNUAL REPORT 2021-02-03
ANNUAL REPORT 2020-02-13
ANNUAL REPORT 2019-02-19
ANNUAL REPORT 2018-02-26
ANNUAL REPORT 2017-01-16
ANNUAL REPORT 2016-02-11
ANNUAL REPORT 2015-02-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339666901 0418800 2014-03-14 1413 U.S. 441, FORT LAUDERDALE, FL, 33317
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-03-14
Emphasis P: FALL, L: FALL
Case Closed 2023-04-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about 14 March, 2014, at the above addressed job site, employees were doing masonry work, placing concrete blocks, while working off a scaffold that was not fully planked.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a. On or about 14 March, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on scaffold that did not have the correct base plates, mud sills, and cross members installed on the scaffold.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a. On or about 14 March, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on scaffold with footings that were not level, rigid, and ones that failed support the amount of weight that was on the scaffold.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a. On or about 14 March, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on scaffold that was missing the proper base plates and was supported by concrete blocks on a sloped surface and thin pieces of wood.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights were not plumb and braced to prevent swaying and displacement: a. On or about 14 March, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on scaffold that was not plumbed or braced while placing concrete blocks to build a wall.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a. On or about 14 March, 2014, at the above addressed job site, employees were exposed to the hazard of falling while climbing the sides of a scaffold to gain access to the working level of the platform.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. On or about 14 March, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on a scaffold that was not inspected by a competent person at the start of the work day.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a. On or about 14 March, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on a scaffold without being trained on recognizing the hazards of working on a scaffold, how to properly erect, dismantle, move, and inspect a scaffold.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19260454 B02
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-15
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b)(2): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question: a. On or about 14 March, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on a scaffold without being trained on recognizing the hazards of working on a scaffold or how to properly erect and inspect a scaffold.

Date of last update: 01 Apr 2025

Sources: Florida Department of State