Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-06-17
|
Case Closed |
2024-12-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1479381 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19260451 B01 I |
Issuance Date |
2020-06-23 |
Current Penalty |
3238.4 |
Initial Penalty |
4048.0 |
Contest Date |
2020-07-20 |
Final Order |
2020-11-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156mpl, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from tubular welded frame scaffolds that were not fully planked. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19260451 B05 I |
Issuance Date |
2020-06-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2020-07-20 |
Final Order |
2020-11-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, an employee worked from a scaffold platform which extended over 56" over its support, which exposed employee to a fall hazard of 5' and 18' approximately to residence balcony floor and ground level, respectively. |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19260451 B07 |
Issuance Date |
2020-06-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2020-07-20 |
Final Order |
2020-11-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(7): On scaffolds where platforms are overlapped to create a long platform, the overlap did not occur only over supports: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, two employees worked from scaffold platforms that overlapped without being supported, which exposed employees to a fall hazard of 5' and 18' approximately to residence balcony floor and ground level, respectively. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260451 C02 |
Issuance Date |
2020-06-23 |
Current Penalty |
3238.4 |
Initial Penalty |
4048.0 |
Contest Date |
2020-07-20 |
Final Order |
2020-11-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from tubular welded frame scaffolds whose frames were placed over concrete but lacked base plates. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19260451 E01 |
Issuance Date |
2020-06-23 |
Current Penalty |
3238.4 |
Initial Penalty |
4048.0 |
Contest Date |
2020-07-20 |
Final Order |
2020-11-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from tubular welded frame scaffolds that lacked a safe means of access. |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19260451 G01 |
Issuance Date |
2020-06-23 |
Current Penalty |
3238.4 |
Initial Penalty |
4048.0 |
Contest Date |
2020-07-20 |
Final Order |
2020-11-30 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, two employees were exposed to the hazard of falling 18'-0" to ground level while working from scaffolds without being protected from falling. b. On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, an employee was exposed to the hazard of falling 12'-0" to ground level while working from scaffolds without being protected from falling. |
|
Citation ID |
01005 |
Citaton Type |
Other |
Standard Cited |
19260452 C02 |
Issuance Date |
2020-06-23 |
Current Penalty |
3238.4 |
Initial Penalty |
4048.0 |
Contest Date |
2020-07-20 |
Final Order |
2020-11-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from a tubular welded frame scaffolds that lacked cross braces in the portion facing wall. |
|
|