Search icon

EKA CONCRETE BUILDERS CORP.

Company Details

Entity Name: EKA CONCRETE BUILDERS CORP.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit
Status: Inactive
Date Filed: 20 Mar 2003 (22 years ago)
Date of dissolution: 15 Sep 2006 (18 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 15 Sep 2006 (18 years ago)
Document Number: P03000032448
FEI/EIN Number 010773217
Address: 27843 SW 129 PLACE, HOMESTEAD, FL, 33032-8505
Mail Address: 27843 SW 129 PLACE, HOMESTEAD, FL, 33032-8505
Place of Formation: FLORIDA

Agent

Name Role Address
NARVAEZ CRISTOBAL Agent 27843 SW 129 PLACE, HOMESTEAD, FL, 330328505

Director

Name Role Address
NARVAEZ CRISTOBAL Director 27843 SW 129 PLACE, HOMESTEAD, FL, 330328505
NARVAEZ MARIA Director 27843 SW 129 PLACE, HOMESTEAD, FL, 330328505

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2006-09-15 No data No data
CANCEL ADM DISS/REV 2004-12-17 No data No data
REGISTERED AGENT NAME CHANGED 2004-12-17 NARVAEZ, CRISTOBAL No data
ADMIN DISSOLUTION FOR ANNUAL REPORT 2004-10-01 No data No data

Documents

Name Date
ANNUAL REPORT 2005-02-01
REINSTATEMENT 2004-12-17
Domestic Profit 2003-03-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339587172 0418800 2014-02-11 2721 N.E. 14 ST., POMPANO BEACH, FL, 33062
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2014-02-12
Emphasis L: FALL, P: FALL
Case Closed 2018-12-20

Related Activity

Type Inspection
Activity Nr 958726
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-05-29
Abatement Due Date 2014-06-10
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-21
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about February 11, 2014 at the above addressed job site, employees were exposed to a fall hazard while conducting concrete forming work from fabricated frame scaffolds that were not fully planked. 2 instances: 1. Employees had used a 10 foot high scaffold that was not fully planked while installing forms on the rake beam. 2. Employees had used an 8 foot high scaffold that was not fully planked while installing forms on the rake beam.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2014-05-29
Abatement Due Date 2014-06-10
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-21
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about February 11, 2014 at the above addressed job site, employees were exposed to a fall hazard while conducting concrete forming work from a deficient fabricated frame scaffolds that lacked guardrails and were not fully planked, that had not been inspected by a competent person. 2 instances: Instance 1: Fabricated frame scaffold two tiers, approximately 10 feet high, 5 feet wide lacking guardrails on side and end and lacked a plank creating about a 9 inch gap. Lower surface of concrete. Instance 2: Fabricated frame scaffold two tiers high, approximately 8 feet high, 5 feet wide that lacked guardrails on side and end and with one and two 9 inch wide planks creating a gap between 40 and 48 inches. Lower surface of concrete.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 F15
Issuance Date 2014-05-29
Abatement Due Date 2014-06-10
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees: a) On or about February 11, 2014, at the above addressed job site, an employee was exposed to a fall hazard while using a  step ladder in the closed position which was leaning against a structure to access a working surface.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2014-05-29
Abatement Due Date 2014-06-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about February 11, 2014, at the above addressed job site, an employee was exposed to a fall hazard while using a step ladder in the closed position which was leaning against a structure to access a working surface.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-05-29
Abatement Due Date 2014-06-10
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-21
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) On or about February 11, 2014, at the above addressed job site, employees were exposed to a fall hazard while performing concrete forming work without a means of conventional fall protection from a fabricated frame scaffold that lacked guardrails.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-05-29
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-21
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about February 11, 2014, employees were exposed to a fall hazard while passing materials up to unguarded window openings on an elevated surface, without means of conventional fall protection.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2014-05-29
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-21
Nr Instances 11
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) On or about February 11, 2014, at the above addressed job site, employees were exposed to a fall hazard while installing reinforcing steel around uncovered / unguarded holes on an elevate surface, without means of conventional fall protection. 11 instances: Instance 1-6: 6 ea. small floor openings on second floor. Instance 7-11: 5 ea. stairwell openings on second floor.
Citation ID 01007
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-05-29
Abatement Due Date 2014-06-10
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-21
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about February 11, 2014, at the above addressed job site, employees were exposed to a fall hazard while using portable extension ladders that did not extend 3 feet above the upper landing. 2 Instances: 1. 1 ea. aluminum extension ladder on west side of scaffold. 2. 1 ea. aluminum extension ladder on south side of scaffold.
308403005 0418800 2005-01-27 5 PIAZZ DELLE PALL, BOYNTON BEACH, FL, 33426
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2005-01-27
Emphasis L: FALL
Case Closed 2006-12-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2005-06-09
Abatement Due Date 2005-06-14
Current Penalty 1500.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2005-06-09
Abatement Due Date 2005-06-21
Current Penalty 1500.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 1
Gravity 10

Date of last update: 03 Feb 2025