343662110
|
0419700
|
2018-12-14
|
951 SW 21 PL, WILLISTON, FL, 32696
|
|
Inspection Type |
Planned
|
Scope |
Records
|
Safety/Health |
Health
|
Close Conference |
2018-12-14
|
Emphasis |
P: LEAD, N: LEAD
|
Case Closed |
2019-03-22
|
|
341939932
|
0419700
|
2016-11-29
|
951 SW 21ST PL, WILLISTON, FL, 32696
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-11-29
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2017-01-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1149790 |
Safety |
Yes |
|
|
341518421
|
0419700
|
2016-06-02
|
951 SW 21ST PL, WILLISTON, FL, 32696
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-06-02
|
Case Closed |
2016-11-30
|
Related Activity
Type |
Referral |
Activity Nr |
1095854 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2016-08-23 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
3608.25 |
Initial Penalty |
4811.0 |
Final Order |
2016-09-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. On or about June 2, 2016, an employee was required to wear a half face piece respirator when applying Valspar spray-on bed liner on under carriages used for horse trailers and the employer did not establish and implement a written respiratory protection program that addressed the worksite-specific procedures such as but not limited to employee medical evaluations, fit testing, and training on the use, maintenance and care of the respirators. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2016-08-23 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-09-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. On or about June 2, 2016 the employer did not ensure that employees required to wear respirators to protect against the hazard of airborne contaminates were provided a medical evaluation to determine the employee's ability to use a respirator before the employees used respirators in the facility. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2016-08-23 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-09-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. On or about June 2, 2016 the employer did not ensure that employees required to use tight-fitting facepiece respirators to protect against the hazard of airborne contaminates in the workplace passed a fit test to determine appropriate fit and seal of the respirators. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100134 K01 |
Issuance Date |
2016-08-23 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-09-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(l ): The employer did not provide effective training to employees who were required to use respirators: a. On or about June 2, 2016 the employer did not ensure that employees who were required to use respirators in the course of their job duties to protect against the hazards of airborne contaminates were effectively trained upon hire initially and thereafter annually. |
|
|
341497907
|
0419700
|
2016-05-11
|
951 SW 21ST PLACE, WILLISTON, FL, 32696
|
|
Inspection Type |
Unprog Other
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-05-11
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2016-08-17
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100213 M01 |
Issuance Date |
2016-05-26 |
Abatement Due Date |
2016-07-14 |
Current Penalty |
6300.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-06-23 |
Nr Instances |
3 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(m)(1): Cutting heads of wood shaper(s) were not enclosed with a cage or adjustable guard so designed so as to keep the operator's hand away from the cutting edge: a) On or about December 8, 2015 an employee was using a Grizzly Brand G9933 multi station wood shaper/ molding cutter that had exposed rotating blades that were not enclosed with a cage or guard so designed to prevent an employee/operator from getting too close to the cutting heads. 1. On December 8, 2015 one employee suffered an amputation injury when his right index finger came in contact with the rotating cutter head. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19040040 A |
Issuance Date |
2016-05-26 |
Current Penalty |
900.0 |
Initial Penalty |
900.0 |
Final Order |
2016-06-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. a). On May 11, 2016, the employer did not provide OSHA 300 and 301 forms or Workers compensation report forms for one employee who suffered an amputation injury while working in the Carpentry Shop of the employer, with four business hours of the request. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040004 A |
Issuance Date |
2016-05-26 |
Current Penalty |
900.0 |
Initial Penalty |
900.0 |
Final Order |
2016-06-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. a). On or about December 8, 2015 the employer did not record the work related amputation of one employee who suffered an amputation injury to his right index finger when it was caught in the rotating blade of a Grizzly, G9933 multi station router table. Abatement Certification and Documentation is required |
|
|
341417806
|
0419700
|
2016-04-20
|
951 SW 21ST PL, WILLISTON, FL, 32696
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-04-20
|
Emphasis |
N: AMPUTATE, L: FORKLIFT
|
Case Closed |
2019-02-13
|
Related Activity
Type |
Complaint |
Activity Nr |
1082744 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2016-07-20 |
Abatement Due Date |
2016-10-05 |
Current Penalty |
4095.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-08-08 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees a. On or about April 21, 2016 the employer was using Polyvinyl Chloride (PVC) pipe to supply compressed air with a gauged air pressure of 120 pounds per square inch (psi) to operate portable hand tools throughout the facility. The PVC pipe was not approved for use with compressed air and could fail or rupture, exposing employees to laceration and puncture hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 L02 |
Issuance Date |
2016-07-20 |
Current Penalty |
4095.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-08-08 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(2): Training program implementation. Power Industrial Trucks. a). On or about April 21, 2016 employees had not received power industrial truck training that consisted of a combination of formal instruction, practical training, and evaluation of the employees operation of the forklifts while in the facility exposing the operators to potential caught in and struck by hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2016-07-20 |
Abatement Due Date |
2016-09-27 |
Current Penalty |
4095.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-08-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about April 20, 2016 employees operating the Amada RG-80 Hydraulic Press Brake were exposed to crushing and caught in hazards because they were not protected by appropriate machine guards. b) On or about March 24, 2016 one employee suffered permanent disabling injuries to his left hand when it was crushed between the die and the tap rail of the Amada RG-80 Mechanical Press Brake. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
2016-07-20 |
Abatement Due Date |
2016-09-06 |
Current Penalty |
4095.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-08-08 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) On or about April 21, 2016 employees were observed using a Sawstop brand 10" cabinet saw to hand feed wood panels to be ripped to size and were exposed to amputation hazards because the saw blade was not covered with an adjustable hood to completely enclose the portion of the blade exposed above the table. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100213 C03 |
Issuance Date |
2016-07-20 |
Abatement Due Date |
2016-09-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-08 |
Nr Instances |
3 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) On or about April 21, 2016 employees operating the hand fed Grizzly Brand table saw were not protected from struck by hazards because the table saw in use daily was not equipped with non-kickback fingers or dogs to prevent blade and material kickbacks. b). On or about April 21, 2016 employees operating the hand fed SawStop Brand 10 inch table saw in the cabinet making area were not protected from struck by hazards because the table saw in use daily was not equipped with non-kickback fingers or dogs to prevent blade and material kickbacks. c). On or about April 21, 2016 employees operating the hand fed SawStop Brand 10 inch table saw by the back wall were not protected from struck by hazards because the table saw in use daily was not equipped with non-kickback fingers or dogs to prevent blade and material kickbacks. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100213 M01 |
Issuance Date |
2016-07-20 |
Abatement Due Date |
2016-09-06 |
Current Penalty |
4095.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-08-08 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(m)(1): Cutting heads of wood shaper(s) were not enclosed with a cage or adjustable guard so designed so as to keep the operator's hand away from the cutting edge: a) On or about April 21, 2016 Employees were using a multi station wood shaper, molding cutter that had exposed rotating blades that were not enclosed with a cage or guard so designed to prevent an employee/operator from getting too close to the cutting heads. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100252 B02 III |
Issuance Date |
2016-07-20 |
Current Penalty |
4095.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-08-08 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) On or about April 20, 2016 employees working and walking in the welding areas are not protected from the arc flash. b). On or about April 28, 2016 employees assembling trailer components were not wearing welding hoods, exposing the employee to the arc flash. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19040004 A |
Issuance Date |
2016-07-20 |
Abatement Due Date |
2016-09-06 |
Current Penalty |
585.0 |
Initial Penalty |
900.0 |
Final Order |
2016-08-08 |
Nr Instances |
3 |
Nr Exposed |
128 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. a). On or about May 29, 2016, one employee Stephen Grabe suffered a crushing injury to his left hand requiring two (2) surgeries and three (3) days of hospitalization, when his hand was caught in an Amada RG-80 Hydraulic Press Brake. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19040032 A03 |
Issuance Date |
2016-07-20 |
Abatement Due Date |
2016-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(a)(3): The employer did not certify an OSHA 300A Form or equivalent. a). On or about April 20, 2016, the employer failed to certify the annual summary of work-related injuries and illnesses. |
|
Citation ID |
02001C |
Citaton Type |
Other |
Standard Cited |
19040040 A |
Issuance Date |
2016-07-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. a). On or about April 20, 2016 the employer did not provide CSHO with the required injury and illness records for the employer within 4 business hours of the request. |
|
Citation ID |
02001D |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2016-07-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA. a). On or about April 21, 2016 the employer did not report the crushing injury to an employees hand who was working in the fabrication section of the facility. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2016-07-20 |
Abatement Due Date |
2016-09-06 |
Current Penalty |
585.0 |
Initial Penalty |
900.0 |
Final Order |
2016-08-08 |
Nr Instances |
1 |
Nr Exposed |
40 |
Related Event Code (REC) |
Accident |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met a). On or about April 20, 2016 the employer did not develop, maintain, communicate or train his employees on all of the chemicals and potential hazards related to the use of Aluminum Brighter, Valspar Paints, Streak Master Ultra Guard, Lacquer, panel glues, Adhesion Promoter, and other flammable liquids used daily in the facility and what appropriate protective measures employees should take to prevent themselves from inhalation, burn and blinding hazards. |
|
|
339444689
|
0419700
|
2013-10-28
|
951 SW 21ST PL, WILLISTON, FL, 32696
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Health
|
Close Conference |
2013-10-28
|
Emphasis |
L: LEAD, N: LEAD, P: LEAD
|
Case Closed |
2013-11-05
|
|