Search icon

CIRILOS' REMODELING, INC. - Florida Company Profile

Company Details

Entity Name: CIRILOS' REMODELING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

CIRILOS' REMODELING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 23 May 2002 (23 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 10 Nov 2010 (14 years ago)
Document Number: P02000057835
FEI/EIN Number 300093766

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 914 LIVEOAK LEAF CT, APOPKA, FL, 32712, US
Mail Address: 914 LIVEOAK LEAF CT, APOPKA, FL, 32712
ZIP code: 32712
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
REYES CIRILO Vice President 914 liveoak leaf ct, APOPKA, FL, 32712
REYES JENNIFER President 914 LIVEOAK LE, APOPKA, FL, 32712
REYES JENNIFER Treasurer 914 LIVEOAK LEAF CT, APOPKA, FL, 32712
REYES JENNIFER Agent 914 LIVEOAK LEAF CT, APOPKA, FL, 32712

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2014-04-30 914 LIVEOAK LEAF CT, APOPKA, FL 32712 -
REGISTERED AGENT ADDRESS CHANGED 2011-05-01 914 LIVEOAK LEAF CT, APOPKA, FL 32712 -
CHANGE OF MAILING ADDRESS 2011-05-01 914 LIVEOAK LEAF CT, APOPKA, FL 32712 -
REINSTATEMENT 2010-11-10 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2010-09-24 - -
AMENDMENT 2008-08-13 - -
REGISTERED AGENT NAME CHANGED 2008-08-13 REYES, JENNIFER -
AMENDMENT 2003-12-18 - -

Documents

Name Date
ANNUAL REPORT 2024-01-31
ANNUAL REPORT 2023-02-07
ANNUAL REPORT 2022-07-14
ANNUAL REPORT 2021-03-04
ANNUAL REPORT 2020-02-20
ANNUAL REPORT 2019-01-17
ANNUAL REPORT 2018-01-09
ANNUAL REPORT 2017-02-01
ANNUAL REPORT 2016-04-14
ANNUAL REPORT 2015-03-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346723778 0419730 2023-05-24 13471 SAGESTONE DR, WINTER GARDEN, FL, 34787
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2023-05-24
Emphasis L: FALL
Case Closed 2023-10-18

Related Activity

Type Inspection
Activity Nr 1672336
Safety Yes
Type Inspection
Activity Nr 1672365
Safety Yes
Type Inspection
Activity Nr 1672355
Safety Yes
Type Inspection
Activity Nr 1673812
Safety Yes
Type Referral
Activity Nr 2034607
Safety Yes
Type Inspection
Activity Nr 1672371
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2023-08-02
Abatement Due Date 2023-08-21
Current Penalty 2679.0
Initial Penalty 4465.0
Final Order 2023-09-14
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 05/24/2023, at the site located at 16055 Scarpetta St. Winter Garden, FL., the sides of the ladder were set by the employer approximately two ( 2) feet past the roof landing, while being used to gain access to a roof (20) feet high, to install shingles, exposing employees to fall hazards.
341288421 0420600 2016-03-01 3029 RUFUSE CT, MELBOURNE, FL, 32940
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-03-01
Emphasis L: FALL, P: FALL
Case Closed 2018-04-12

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2016-05-05
Current Penalty 16170.0
Initial Penalty 26950.0
Final Order 2016-05-26
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a.) On the 6/12 pitched roof of a residential property, employees installing a tile roof were not protected from falling approximately 10 feet 5 inches, on or about 2/24/16. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1093998, citation number 1, item number 1 and was affirmed as a final order on 1/29/16, with respect to a workplace located at 1723 Woodpath Drive, Auburndale, FL. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1048586, citation number 2, item number 1and was affirmed as a final order on 5/20/15, with respect to a workplace located at 5321 Bentpine Cove Road, Duval, FL. Cirlios' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 998448, citation number 1, item number 1 and was affirmed as a final order on 12/1/2014, with respect to a workplace located at 3100 Lucena Lane, Lot 55, Jacksonville, FL. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 977080, citation number 1, item number 1 and was affirmed as a final order on 6/20/14, with respect to a workplace located at Lot 19, Saint Augustine, FL. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 965990, citation number 1, item number 1 and was affirmed as a final order on 5/28/2014, with respect to a workplace located at Waterside Point, Groveland, FL. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 943717, citation number 1, item number 2 and was affirmed as a final order on 2/14/2014, with respect to a workplace located at 1205 Legg Drive, Lot 1130, Apopka, FL.
341213015 0420600 2016-01-29 5135 CROWN HAVEN DRIVE 300, KISSIMMEE, FL, 34746
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-01-29
Emphasis P: FALL, L: FALL
Case Closed 2017-04-06

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2016-02-29
Current Penalty 20790.0
Initial Penalty 34650.0
Final Order 2016-03-21
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the 5/12 pitched roof of a residential property, employees installing water barrier material were not protected from falling approximately 17 feet 5 inches, on or about 1/29/16. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1093998, citation number 1, item number 1 and was affirmed as a final order on 1/29/16, with respect to a workplace located at 1723 Woodpath Drive, Auburndale, FL. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1048586, citation number 2, item number 1and was affirmed as a final order on 5/20/15, with respect to a workplace located at 5321 Bentpine Cove Road, Duval, FL. Cirlios' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 998448, citation number 1, item number 1 and was affirmed as a final order on 12/1/2014, with respect to a workplace located at 3100 Lucena Lane, Lot 55, Jacksonville, FL. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 977080, citation number 1, item number 1 and was affirmed as a final order on 6/20/14, with respect to a workplace located at Lot 19, Saint Augustine, FL. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 965990, citation number 1, item number 1 and was affirmed as a final order on 5/28/2014, with respect to a workplace located at Waterside Point, Groveland, FL. Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 943717, citation number 1, item number 2 and was affirmed as a final order on 2/14/2014, with respect to a workplace located at 1205 Legg Drive, Lot 1130, Apopka, FL.
340939982 0420600 2015-09-22 1723,1727 WOODPATH DR, AUBURNDALE, FL, 33823
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-09-22
Emphasis L: FALL, P: FALL
Case Closed 2017-02-13

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2016-01-06
Current Penalty 19250.0
Initial Penalty 38500.0
Final Order 2016-01-29
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For employees working at Lots 68 and 69 on Wood Path located in Auburndale, as observed on or about September 22, 2015. Employees working on the roof at 18 feet height were not protected from falling by any fall protection systems. The Cirilos' Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 1048586, citation number 2, item number 1 and was affirmed as a final order on 5/20/2015, with respect to a workplace located at 5321 Bentpine Cove Road in Duval, FL 32224.
340485861 0419700 2015-03-24 5381 BENTPINE COVE ROAD, JACKSONVILLE, FL, 32224
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2015-03-24
Emphasis L: FALL, P: FALL
Case Closed 2017-06-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2015-04-29
Current Penalty 3080.0
Initial Penalty 3080.0
Final Order 2015-05-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a. On or about March 24, 2015, at the east and west side of the roof, employees operating portable electric hand held saws for cutting roofing tiles were not wearing eye protection, being exposed to get struck-by flying debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-04-29
Abatement Due Date 2015-05-05
Current Penalty 2310.0
Initial Penalty 2310.0
Final Order 2015-05-20
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about March 24, 2015, at the rooftop of the residence, employees performing roof work on a steep-pitch roof 6 feet or more above ground were not properly trained in the use of personal fall arrest systems.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2015-04-29
Current Penalty 37300.0
Initial Penalty 53900.0
Final Order 2015-05-20
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the East Side, an employee installing roofing tiles on a 7:12 pitch roof is exposed to a 14 feet fall hazard to a lower rooftop level, without the use of personal fall arrest system, safety net system or guardrail system. b. At the West Side, an employee installing roofing tiles on a 7:12 pitch roof is exposed to a 27 feet fall hazard to a lower rooftop level, without the use of personal fall arrest system, safety net system or guardrail system. c. At the West Side, an employee installing roofing tiles on a 7:12 pitch roof is exposed to a 14 feet fall hazard to a lower rooftop level, without the use of personal fall arrest system, safety net system or guardrail system. The employer fails to assure effective protection against falls as required by the standard, as demonstrated on March 24, 2015, when employees were installing roofing tiles of a residential house at 5381 Bentpine Cove Road, Jacksonville, Florida 32224 without fall protections and were exposed to fall hazards of 14 and 27 feet above the lower level. Cirilos Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 998448, citation number 01, item number 001 and was affirmed as a final order on December 01, 2014, with respect to a workplace located at 3100 Lucena Lanelot 55, Jacksonville, FL. Cirilos Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 977080, citation number 01, item number 001 and was affirmed as a final order on June 20, 2014, with respect to a workplace located at Lot 19, Saint Augustine FL. Cirilos Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 965990, citation number 01, item number 001 and was affirmed as a final order on May 13, 2014, with respect to a workplace located at Waterside Point, Groveland FL. Cirilos Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 943717, citation number 01, item number 002 and was affirmed as a final order on February 18, 2014, with respect to a workplace located at 1205 Legg Drivelot 1130, Apopka FL. To abate this violation, the employer must ensure that all employees wear appropriate fall protection or install a guardrail or safety net system when an employee works above 6 feet off the surface. Pursuant to 29 CFR 1903.19, the employer must submit documents describing the steps it is taking to ensure compliance, including and explanation of how these steps protect its employees from fall hazards.
339659906 0420600 2014-02-20 WATERSIDE POINT, GROVELAND, FL, 34736
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-02-20
Emphasis L: FALL, P: FALL
Case Closed 2014-06-03

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-04-17
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2014-05-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) At the jobsite - employees were exposed to a fall of up to approximately 18 feet while conducting various roofing activities, observed on or about 2/20/14.
339437170 0420600 2013-09-25 1205 LEGG DRIVE LOT 1130, APOPKA, FL, 32712
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-09-26
Emphasis L: FALL, P: FALL
Case Closed 2016-12-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-12-26
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2014-02-18
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a). At the D.R. Horton developoment in the Rock Springs Ridge subdevision, employees installing roof shingles climbed thru the second story window and walked along the roof overhand of the single family home being constructed to gain access to the ladder exposing them to the 8-foot fall hazard of the open side of the roof overhang as observed on or about September 25, 2013.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2013-12-26
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2014-02-18
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a). At Lot-1130 of the D.R. Horton developoment in Rock Springs Ridge, Apopka, two employees installing shingles onto the 5:12 pitched roof were not using a conventional or alternative fall protection system to protect them from an 18-foot fall hazard as observed on or about September 25, 2013.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-12-26
Current Penalty 2268.0
Initial Penalty 3780.0
Final Order 2014-02-18
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a). At Lot 1130 of the D.R. Horton development in Rock Springs Ridge, the ladder used by the employees to gain access and egress from the 5:12 pitched roof was not positioned the required minimum of 3 feet above the roof landing.

Date of last update: 02 Apr 2025