Search icon

BAKER CONSTRUCTION ENTERPRISES, INC. - Florida Company Profile

Company Details

Entity Name: BAKER CONSTRUCTION ENTERPRISES, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

BAKER CONSTRUCTION ENTERPRISES, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 16 Jan 2002 (23 years ago)
Date of dissolution: 15 Sep 2006 (19 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 15 Sep 2006 (19 years ago)
Document Number: P02000005411
FEI/EIN Number 043612880

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1101 GULF BREEZE PKWY, BLG 3 SUITE 6, GULF BREEZE, FL, 32561
Mail Address: 1101 GULF BREEZE PKWY, BLG 3 SUITE 6, GULF BREEZE, FL, 32561
ZIP code: 32561
County: Santa Rosa
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BAKER ELMER E President 801 MANDANADO DRIVE, GULF BREEZE, FL, 32561
BAKER ELMER E Secretary 801 MANDANADO DRIVE, GULF BREEZE, FL, 32561
BAKER ELMER E Treasurer 801 MANDANADO DRIVE, GULF BREEZE, FL, 32561
LANMAN ROBERT W Agent 2946 RANCHETTE SQUARE, GULF BREEZE, FL, 32563

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2006-09-15 - -
CHANGE OF PRINCIPAL ADDRESS 2005-04-29 1101 GULF BREEZE PKWY, BLG 3 SUITE 6, GULF BREEZE, FL 32561 -
CHANGE OF MAILING ADDRESS 2005-04-29 1101 GULF BREEZE PKWY, BLG 3 SUITE 6, GULF BREEZE, FL 32561 -
REGISTERED AGENT ADDRESS CHANGED 2005-04-29 2946 RANCHETTE SQUARE, GULF BREEZE, FL 32563 -

Documents

Name Date
ANNUAL REPORT 2005-04-29
ANNUAL REPORT 2004-04-30
ANNUAL REPORT 2003-05-05
Domestic Profit 2002-01-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344559471 0418800 2020-01-09 550 QUADRILLE BLVD, WEST PALM BEACH, FL, 33401
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2020-01-09
Emphasis L: FALL
Case Closed 2021-09-14

Related Activity

Type Inspection
Activity Nr 1455394
Safety Yes
Type Inspection
Activity Nr 1455405
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2020-05-27
Current Penalty 7711.2
Initial Penalty 9639.0
Contest Date 2020-06-15
Final Order 2021-08-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall and caught-in-between hazards from unstable structures: On the 13th floor: On or about January 9, 2020 and at times prior, the employer exposed employees to falls and caught-in-between hazards due to a rebar cage that was not adequately secured and braced.
Citation ID 01002
Citaton Type Other
Standard Cited 19261052 C04 IV
Issuance Date 2020-05-27
Current Penalty 11566.0
Initial Penalty 11566.0
Contest Date 2020-06-15
Final Order 2021-08-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(4)(iv): Structural members in stairrail systems were not installed such that there were no openings in the stairrail system that were more than 19 inches (48 cm) wide: On the 13th floor: On or about 1/9/2020 and at times prior, the employer exposed employees to fall hazards due to lack of guardrails or other structural members in the stairrail system between the 12th and the 13th floor.

Date of last update: 01 Apr 2025