Search icon

M & L CONSTRUCTION, INC. - Florida Company Profile

Company Details

Entity Name: M & L CONSTRUCTION, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

M & L CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 26 Dec 2001 (23 years ago)
Date of dissolution: 14 Sep 2007 (18 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 14 Sep 2007 (18 years ago)
Document Number: P01000121686
FEI/EIN Number 260007362

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7272 MELVIN RD, JACKSONVILLE, FL, 32210
Mail Address: 7272 MELVIN RD, JACKSONVILLE, FL, 32210
ZIP code: 32210
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
QUASHIE LANCELOT W Director 7272 MELVIN RD, JACKSONVILLE, FL, 32210
VANN MICHAEL A Director 10929 BONNELLY DR, JACKSONVILLE, FL, 32218
JOHNSON EDWARD Director 11011 HARTS RD #602, JACKSONVILLE, FL, 32218
QUASHIE LANCELOT W Agent 7272 MELVIN RD, JACKSONVILLE, FL, 32210

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2007-09-14 - -

Documents

Name Date
ANNUAL REPORT 2006-05-01
ANNUAL REPORT 2005-02-07
ANNUAL REPORT 2004-04-27
ANNUAL REPORT 2003-05-01
ANNUAL REPORT 2002-07-16
Domestic Profit 2001-12-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339765406 0420600 2014-05-08 2931 WEST HILLSBOROUGH AVENUE, TAMPA, FL, 33614
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-05-08
Emphasis L: EISAX, L: EISAOF, L: FALL, P: FALL
Case Closed 2014-06-27

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2014-06-17
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-06-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) For employees working at 2931 West Hillsborough Avenue in Tampa, as observed on or about May 08, 2014. Employees were installing sheathing on a roof with a 5:12 pitch. The eave to ground height was approximately 10 feet and the employees had no fall protection system in place.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-06-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) For employees working at 2931 West Hillsborough Avenue in Tampa, as observed on or about May 08, 2014. Employees were on the second floor installing trusses and framework with an unprotected edge along the stairway to the first floor. The second floor to ground height was approximately 9 feet 6 inches and the employees had no fall protection system in place.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2014-06-17
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2014-06-27
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed): a) For employees working at 2931 West Hillsborough Avenue in Tampa, as observed on or about May 08, 2014. Employees were using a step ladder to access the upper working surface. The step ladder was closed and leaning against the outer wall and not used for the purpose it was designed. Step ladders are not designed to be used in the closed position for access to an upper landing surface.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2014-06-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-27
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) For employees working at 2931 West Hillsborough Avenue in Tampa, as observed on or about May 08, 2014. Employees were using a step ladder to access the upper working surface. The employees were using the top step and top as a step to access the upper working surface.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-06-17
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-06-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) For employees working at 2931 West Hillsborough Avenue in Tampa, as observed on or about May 08, 2014. Employees were on the roof beneath a suspended load of plywood sheathing being lifted by a crane without wearing any head protection. Employees were exposed to an impact hazard.
Citation ID 02001A
Citaton Type Other
Standard Cited 19260403 B02
Issuance Date 2014-06-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-27
Nr Instances 2
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) For employees working at 2931 West Hillsborough Avenue in Tampa, as observed on or about May 08, 2014. Employees were using 2 metal outlet boxes powered by a flexible cord as temporary power outlets to provide power to tools. Metal boxes are not designed to be used as temporary power unless securely mounted and permanently wired.
Citation ID 02001B
Citaton Type Other
Standard Cited 19260404 F06
Issuance Date 2014-06-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-27
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) For employees working at 2931 West Hillsborough Avenue in Tampa, as observed on or about May 08, 2014. Employees using an extension cord to supply power to electrical tools. Extension cord in use did not have the ground prong so the path to ground was not permanent and continuous.

Date of last update: 02 Apr 2025