347438400
|
0420600
|
2024-04-25
|
SHRINER STREET, LAND O LAKES, FL, 34638
|
|
Inspection Type |
Complaint
|
Scope |
NoInspection
|
Safety/Health |
Health
|
Close Conference |
2024-04-25
|
Case Closed |
2024-04-25
|
Related Activity
Type |
Complaint |
Activity Nr |
2154846 |
Health |
Yes |
|
|
343457487
|
0420600
|
2018-09-12
|
28714 LUCERO LANE, WESLEY CHAPEL, FL, 33543
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-09-12
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-09-17
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-10-30 |
Current Penalty |
2217.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-11-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) At 28714 Lucerno Lane, an employee in the process of decking the 4:12 pitch roof was exposed to a fall hazard of 9'4", in that the rope lanyard utilized as part of a personal fall arrest system was 46 foot in length. Observed on or about 09/12/2018. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260502 D15 |
Issuance Date |
2018-10-30 |
Current Penalty |
2217.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-11-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. (a) At 28714 Lucerno Lane- An employee in the process of decking the 4:12 slope pitch roof was exposed to a 9'4" fall hazard, in that an anchorage point was not utilized. Rope lanyard was wrapped around a roof truss. Observed on or about 09/12/2018. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 A02 |
Issuance Date |
2018-10-30 |
Current Penalty |
2217.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-11-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(a)(2): Ladder rungs, cleats, and/or steps were not parallel, level, and uniformly spaced when the ladder was in position for use: (a) At 28714 Lucerno Lane- An employee handing materials and tools to co-workers on the roof was exposed to an 8 feet fall hazard, in that, the "A" frame step ladder being used was not open and in the locked position, resulting in the ladder rungs not being level, as observed on or about 09/12/2018. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2018-10-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-11-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) At 28714 Lucerno Lane- An employee in the process of handing materials and tools to co-workers on the roof was exposed to a fall hazards up to a 8 feet, in that, the employee was utilizing an "A" frame step ladder as a single ladder, observed on or about 09/12/2018. |
|
|
343001020
|
0420600
|
2018-03-07
|
9920 SMARTY JONES DR., RIVERVIEW, FL, 33569
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-03-07
|
Emphasis |
L: FALL
|
Case Closed |
2018-07-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-06-22 |
Current Penalty |
1496.4 |
Initial Penalty |
2494.0 |
Final Order |
2018-07-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) At the site - The employees were exposed to a fall of 8 feet while standing on the block wall. The employees were installing the rebar, on or about 03/07/2018. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2018-06-22 |
Current Penalty |
636.0 |
Initial Penalty |
1060.0 |
Final Order |
2018-07-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) At the site - An employee was exposed to a fall of 8 feet while using a 8 foot self supporting ladder(A-frame) as a non self supporting ladder(straight ladder). The A-frame ladder was folded and used to access the block wall., on or about 03/07/2018. |
|
|
339244303
|
0420600
|
2013-07-31
|
2609-2627 LANTERN HILL AVE., BRANDON, FL, 33511
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-07-31
|
Emphasis |
L: EISAOF, L: EISAX, L: FALL, P: FALL
|
Case Closed |
2016-05-17
|
Related Activity
Type |
Inspection |
Activity Nr |
924445 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-08-13 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-11-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about 07/31/2013, at the job site - employees walking on the top of the block walls tying rebar were exposed to a fall hazard, in that, fall protection equipment was not provided for employees, exposing the employees to an 11 feet 9 inches and 9 feet 11 inches fall hazards. |
|
|
338926496
|
0420600
|
2013-02-28
|
3272 BERWICK LANE, LAKELAND, FL, 33810
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-02-28
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-04-23
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2013-03-29 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-04-26 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights: a. At the site, employees were exposed to a 5 feet fall hazard, while working on a scaffold one frame high, without having the working platforms fully planked, on or about 02/28/2013. |
|
|
314152752
|
0420600
|
2009-12-16
|
OAK CREEK SUBDIVISION, RIVERVIEW, FL, 33578
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-12-16
|
Emphasis |
L: FALL
|
Case Closed |
2010-06-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2010-01-28 |
Abatement Due Date |
2010-02-02 |
Current Penalty |
337.5 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 F04 |
Issuance Date |
2010-01-28 |
Abatement Due Date |
2010-02-02 |
Current Penalty |
337.5 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
312550114
|
0420600
|
2008-08-15
|
11400 MARBELLA PALM CT., ORLANDO, FL, 32819
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-08-15
|
Emphasis |
L: FALL
|
Case Closed |
2014-05-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2008-09-08 |
Abatement Due Date |
2008-09-18 |
Current Penalty |
225.0 |
Initial Penalty |
225.0 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2008-09-08 |
Abatement Due Date |
2008-09-16 |
Current Penalty |
1500.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2008-09-08 |
Abatement Due Date |
2008-10-11 |
Current Penalty |
225.0 |
Initial Penalty |
225.0 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
01 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 H |
Issuance Date |
2008-09-08 |
Abatement Due Date |
2008-10-11 |
Current Penalty |
225.0 |
Initial Penalty |
225.0 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260503 B01 |
Issuance Date |
2008-09-08 |
Abatement Due Date |
2008-10-11 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
01 |
|
|