Search icon

HANSON ROOFING, INC. - Florida Company Profile

Company Details

Entity Name: HANSON ROOFING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

HANSON ROOFING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 08 Nov 2001 (23 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 22 Jan 2016 (9 years ago)
Document Number: P01000108213
FEI/EIN Number 470850595

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 121 E MOCCASIN CREEK Lane, Palatka, FL, 32177, US
Mail Address: 121 E MOCCASIN CREEK Lane, Palatka, FL, 32177, US
ZIP code: 32177
County: Putnam
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
HANSON JEFFREY D President 1137 SUNNYMEADE DR., JACKSONVILLE, FL, 32211
HANSON JEFFREY D Agent 121 E MOCCASIN CREEK Lane, Palatka, FL, 32177

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2024-11-21 121 E MOCCASIN CREEK Lane, Palatka, FL 32177 -
CHANGE OF MAILING ADDRESS 2024-11-21 121 E MOCCASIN CREEK Lane, Palatka, FL 32177 -
CHANGE OF PRINCIPAL ADDRESS 2024-11-21 121 E MOCCASIN CREEK Lane, Palatka, FL 32177 -
REINSTATEMENT 2016-01-22 - -
REGISTERED AGENT NAME CHANGED 2016-01-22 HANSON, JEFFREY D -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -
PENDING REINSTATEMENT 2013-06-19 - -
REINSTATEMENT 2013-06-18 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2011-09-23 - -
REINSTATEMENT 2010-02-24 - -

Documents

Name Date
ANNUAL REPORT 2025-01-22
AMENDED ANNUAL REPORT 2024-11-21
ANNUAL REPORT 2024-01-19
ANNUAL REPORT 2023-04-18
AMENDED ANNUAL REPORT 2022-03-10
ANNUAL REPORT 2022-03-09
ANNUAL REPORT 2021-03-02
ANNUAL REPORT 2020-03-02
ANNUAL REPORT 2019-04-08
ANNUAL REPORT 2018-04-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343727921 0419700 2019-01-18 1729 NORTH 10TH ST, JACKSONVILLE BEACH, FL, 32250
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-01-18
Emphasis L: FALL, P: FALL
Case Closed 2019-03-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-02-08
Current Penalty 2727.6
Initial Penalty 4546.0
Final Order 2019-02-26
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about January 18, 2019, on the 4:12 pitch roof, five employees installing a new roof system were exposed to fall hazards ranging in height from 8 feet to 13 feet from the eaves and raked edges in that they were not protected by a fall protection system.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2019-02-08
Current Penalty 1818.6
Initial Penalty 3031.0
Final Order 2019-02-26
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about January 18, 2019, at the south edge of the carport, the aluminum extension ladder used to access the roof was extended 16 inches above the edge of the upper landing surface, exposing 5 employees to an 8 feet fall hazard.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2019-02-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-02-26
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a. On or about January 18, 2019, at the south edge of the carport, the roof access ladder was placed at a 63-degree shallow angle that could have allowed the ladder to slide outward, exposing employees to an 8 feet fall hazard.