Search icon

M.M.P. PAINTING, INC. - Florida Company Profile

Company Details

Entity Name: M.M.P. PAINTING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

M.M.P. PAINTING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 10 Sep 2001 (24 years ago)
Last Event: AMENDMENT
Event Date Filed: 16 Mar 2020 (5 years ago)
Document Number: P01000089823
FEI/EIN Number 651136082

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 9054 KENDALE CT, LAKE WORTH, FL, 33467, US
Mail Address: 9054 KENDALE CT, LAKE WORTH, FL, 33467, US
ZIP code: 33467
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PERERA MODESTO M President 9054 KENDALE CT, LAKE WORTH, FL, 33467
PERERA MODESTO M Director 9054 KENDALE CT, LAKE WORTH, FL, 33467
PERERA IVONNE C Vice President 9054 KENDALE CT, LAKE WORTH, FL, 33467
PERERA IVONNE C Director 9054 KENDALE CT, LAKE WORTH, FL, 33467
PERERA MODESTO M Agent 9054 KENDALE CT, LAKE WORTH, FL, 33467

Events

Event Type Filed Date Value Description
AMENDMENT 2020-03-16 - -
CHANGE OF PRINCIPAL ADDRESS 2013-04-24 9054 KENDALE CT, LAKE WORTH, FL 33467 -
CHANGE OF MAILING ADDRESS 2013-04-24 9054 KENDALE CT, LAKE WORTH, FL 33467 -
REGISTERED AGENT ADDRESS CHANGED 2013-04-24 9054 KENDALE CT, LAKE WORTH, FL 33467 -

Documents

Name Date
ANNUAL REPORT 2024-04-08
ANNUAL REPORT 2023-04-06
ANNUAL REPORT 2022-04-19
ANNUAL REPORT 2021-03-17
ANNUAL REPORT 2020-04-27
Amendment 2020-03-16
ANNUAL REPORT 2019-03-20
ANNUAL REPORT 2018-04-27
ANNUAL REPORT 2017-02-15
ANNUAL REPORT 2016-01-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337671010 0418800 2012-12-03 9000 NORTH FEDERAL HIGHWAY, BOCA RATON, FL, 33432
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-12-03
Emphasis L: EISAOF, L: FALL, P: FALL
Case Closed 2013-02-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 IV
Issuance Date 2013-01-10
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-01-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: On the west exterior elevation of a building under renovation located at 900 North Federal Highway in Boca Raton, Florida: Two employees performing painting operations approximately 30 ft. above a lower level from the basket of an aerial lift were standing on the midrail of that basket.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-01-10
Abatement Due Date 2013-01-30
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-01-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On site of a building under renovation located at 900 North Federal Highway in Boca Raton, Florida: The employer did not provide a training program for employees performing painting operations from the basket of an aerial lift that would enable them to recognize the hazards of falling, on or about December 3, 2012. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260502 D21
Issuance Date 2013-01-10
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-01-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: On the west exterior elevation of a building located at 900 North Federal Highway in Boca Raton, Florida: Safety harnesses and lanyards being used by employees performing painting work from the basket of an aerial lift did not inspect their personal fall arrest systems prior to using them. There were defects including but not limited to rusted hasps on the end of the lanyards that would not allow them to either open or automatically close when released, on or about December 3, 2012.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260502 D23
Issuance Date 2013-01-10
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-01-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(23): Personal fall arrest systems were attached to guardrail systems or to hoists: Employees performing painting work from the basket of an aerial lift approximately 30 ft. above a lower level had the lanyards of their personal fall arrest systems attached to the guardrail system of that lift and not to the anchor points provided on the lift by the manufacturer, on or about December 3, 2012.