Search icon

MAB STUCCO, INC. - Florida Company Profile

Company Details

Entity Name: MAB STUCCO, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

MAB STUCCO, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 04 Sep 2001 (23 years ago)
Document Number: P01000087668
FEI/EIN Number 593742954

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: P O B 676, THONOTOSASSA, FL, 33592
Mail Address: POST OFFICE BOX 676, THONOTOSASSA, FL, 33592
ZIP code: 33592
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BURGESS MICHAEL President POST OFFICE BOX 676, THONOTOSASSA, FL, 33592
BURGESS MORVIE Director POST OFFICE BOX 676, THONOTOSASSA, FL, 33592
BURGESS MORVIE Secretary POST OFFICE BOX 676, THONOTOSASSA, FL, 33592
BURGESS MICHAEL Agent 5219 Ehrlich Road, Tampa, FL, 33624

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2018-04-24 5219 Ehrlich Road, Tampa, FL 33624 -
CHANGE OF PRINCIPAL ADDRESS 2009-04-22 P O B 676, THONOTOSASSA, FL 33592 -
CHANGE OF MAILING ADDRESS 2009-04-22 P O B 676, THONOTOSASSA, FL 33592 -
REGISTERED AGENT NAME CHANGED 2004-05-03 BURGESS, MICHAEL -

Documents

Name Date
ANNUAL REPORT 2024-01-30
ANNUAL REPORT 2023-01-30
ANNUAL REPORT 2022-02-23
ANNUAL REPORT 2021-02-17
ANNUAL REPORT 2020-01-28
ANNUAL REPORT 2019-01-22
ANNUAL REPORT 2018-04-24
ANNUAL REPORT 2017-04-04
ANNUAL REPORT 2016-02-28
ANNUAL REPORT 2015-04-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339161390 0420600 2013-06-26 10713 PICTORIA PARK DR., TAMPA, FL, 33647
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-06-26
Emphasis L: FALL, L: EISAX, L: EISAOF, P: FALL
Case Closed 2013-09-12

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-08-15
Current Penalty 816.0
Initial Penalty 1360.0
Final Order 2013-09-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On the West side of the roof -- during the application of stucco, fall protection was not required for employees working on a roof 10-ft from the eave to ground. The pitch of the roof was 5/12, on or about June 26, 2013.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-08-15
Current Penalty 816.0
Initial Penalty 1360.0
Final Order 2013-09-09
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) On the West side - During the application of stucco employees were working on a scaffold that was not fully planked, exposing employees to a 13-8-ft fall hazard, on or about June 26, 2013.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2013-08-15
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-09-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights were not plumb and braced to prevent swaying and displacement. (a) On the west side of the building - during the application of stucco an employee was working on a platform that was supported by a frame frame scaffold that was leaning against the vertical wall of the building an angle on the roof of the overhang with a pitch of 5/12 with only two of the four legs partially anchored, exposing employees to fall hazards 10-ft, on or about June 26, 2013.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-08-15
Current Penalty 612.0
Initial Penalty 1020.0
Final Order 2013-09-09
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) West side of the building - an employees was exposed to a fall of 13.8 feet while using the end frames to access and egress the scaffold, on or about June 26, 2013.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 H02 II
Issuance Date 2013-08-15
Current Penalty 612.0
Initial Penalty 1020.0
Final Order 2013-09-09
Nr Instances 1
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:Note: This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toeboards. A) On the scaffold - A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, on or about June 26, 2013.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2013-08-15
Abatement Due Date 2013-09-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-09
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) The employer did not establish written records of training for the employees,, on or about June 26, 2013.

Date of last update: 03 Feb 2025