Search icon

GUPPY'S MOBILE/MODULAR TRANSPORT INC. - Florida Company Profile

Company Details

Entity Name: GUPPY'S MOBILE/MODULAR TRANSPORT INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GUPPY'S MOBILE/MODULAR TRANSPORT INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 14 Jun 2001 (24 years ago)
Date of dissolution: 23 Sep 2016 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (9 years ago)
Document Number: P01000059536
FEI/EIN Number 593725540

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 8808 FLORIDA ROCK RD., SUITE 109, ORLANDO, FL, 32824
Mail Address: 25551 CELESTIAL STREET, CHRISTMAS, FL, 32709
ZIP code: 32824
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GUPPENBERGER DANIEL Director 8808 FLORIDA ROCK RD., ORLANDO, FL, 32824
WASILESKI CARL Agent 507 PALM AVENUE, TITUSVILLE, FL, 32796

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G10000116996 LIGHTNING DELIVERY, INC. EXPIRED 2010-12-21 2015-12-31 - 25551 CELESTIAL STREET, CHRISTMAS, FL, 32709

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -
CHANGE OF PRINCIPAL ADDRESS 2009-04-12 8808 FLORIDA ROCK RD., SUITE 109, ORLANDO, FL 32824 -
CHANGE OF MAILING ADDRESS 2009-04-12 8808 FLORIDA ROCK RD., SUITE 109, ORLANDO, FL 32824 -

Documents

Name Date
ANNUAL REPORT 2015-04-20
ANNUAL REPORT 2014-01-20
ANNUAL REPORT 2013-01-28
ANNUAL REPORT 2012-02-01
ANNUAL REPORT 2011-02-03
ANNUAL REPORT 2010-03-30
ANNUAL REPORT 2009-04-12
ANNUAL REPORT 2008-04-10
ANNUAL REPORT 2007-04-03
ANNUAL REPORT 2006-04-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334400934 0418800 2012-05-15 10000 INNOVATION WAY, PORT SAINT LUCIE, FL, 34952
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-05-15
Emphasis L: FALL
Case Closed 2013-01-28

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2012-06-27
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2012-07-31
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted: On the roof of a mobile trailer on the north end of a construction site located at 10000 Innovation Way in Port Saint Lucie, Florida: Employees performing roof work on a low slope roof approximately 13 ft. 6 inches above a lower level were not protected from falling to that lower level, on or about May 15, 2012.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2012-06-27
Abatement Due Date 2012-07-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-31
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On a construction site located at 10000 Innovation Way in Port Saint Lucie, Florida: Employees performing roof work on a low slope roof approximately 13 ft. 6 inches above a lower level were not provided with a training program for them to recognize fall hazards, on or about May 15, 2012.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2012-06-27
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2012-07-31
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On the roof edge of a mobile trailer located on the north end of a construction site located at 10000 Innovation Way in Port Saint Lucie, Florida: Employees gaining access to a low slope roof approximately 13 ft. 6 inches above a lower level using a portable ladder did not have the side rails of that ladder extending at least 3 ft. past the upper landing surface, on or about May 15, 2012.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B06
Issuance Date 2012-06-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-31
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: On the roof edge of a mobile trailer located on the north end of a construction site located at 10000 Innovation Way in Port Saint Lucie, Florida: Employees gaining access to a low slope roof approximately 13 ft. 6 inches above a lower level using a portable ladder did not have that ladder secured to prevent accidental displacement, on or about May 15, 2012.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2012-06-27
Abatement Due Date 2012-07-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-31
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: On a construction site located at 10000 Innovation Way in Port Saint Lucie, Florida: The employer did not provide a training program for employees using ladders to gain access to a work level, on or about May 15, 2012.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2012-06-27
Abatement Due Date 2012-07-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-31
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. On a construction site located at 10000 Innovation Way in Port Saint Lucie, Florida: The company did not implement a safety and health program, on or about May 15, 2012.

Date of last update: 02 Apr 2025

Sources: Florida Department of State